4-30 BA EZ17 en* 1.1 * ez17i400.fm
4 Putting into operation
1. Insert the starting key.
2. Turn the starting key to position 1.
3. All control lamps light up for a few seconds.
➥ If a control lamp does not function, contact a Wacker Neuson service
center.
4. Turn and hold the ignition key in position 2 until indicator light 30
(preheating) goes out.
➥ Charge indicator light 28 illuminates.
➥ Indicator light 29 for the engine oil pressure illuminates.
5. Turn the starting key to position 3 until the engine runs.
➥ All indicator lights go out.
➥ If the engine does not start after 20 seconds:
6. Interrupt the start procedure and repeat it after two minutes.
➥ If the engine still does not start after a few tries, contact a Wacker
Neuson service center and have the error rectified.
7. Release the starting key as soon as the engine runs.
The engine will not start unless the control lever base is raised.
Warm-up phase of machine
After the engine has started, allow it to warm up at slightly increased idling
speed until the coolant reaches its operating temperature of about 80 °C
(176 °F).
Do not let the machine warm up at standstill.
Check for unusual noise, exhaust color, leaks, malfunctions, or damage.
In case of malfunctions, damage, or leaks:
Secure the machine, park it and find out the cause for the damage and
have it repaired.
Fold up the control lever base after shutting off G the engine.