EasyManua.ls Logo

Waeco AirCon Service Center User Manual

Waeco AirCon Service Center
68 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
AirConServiceCenter
VAS 6380B / VAS 6381B
Air conditioning service unit
Operating manual
WaecoVAS6380B-6381B_OPM_4445101232_AMER(us)_202x-xx-xx.book Seite 1 Montag, 2. November 2020 4:18 16

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Waeco AirCon Service Center and is the answer not in the manual?

Waeco AirCon Service Center Specifications

General IconGeneral
BrandWaeco
ModelAirCon Service Center
CategoryService Equipment
LanguageEnglish

Summary

About this operating manual

Hotline

Contact information for further assistance with the AirCon Service Center.

Explanation of symbols in this operating manual

Details the meaning of various symbols and formatting used in the manual.

Safety

General safety instructions

Provides essential safety guidelines for operating the AirCon Service Center.

Operating the device safely

Instructions for the safe operation of the AirCon Service Center.

Handling refrigerant safely

Guidelines and precautions for handling refrigerants safely.

Operational measures when using the unit

Operational measures and training requirements for using the unit.

Warnings on the AirCon Service Center

Key warnings and precautions related to the AirCon Service Center.

Safety devices

Description of the built-in safety mechanisms of the AirCon Service Center.

Scope of delivery

Accessories

Proper use

Overview of the AirCon Service Center

Front

Identifies and describes the components on the front of the AirCon Service Center.

Rear

Identifies and describes the components on the rear of the AirCon Service Center.

Initial startup

Setting up and switching on

Step-by-step guide for setting up and powering on the AirCon Service Center.

Standby menu

Explains the information displayed in the standby menu.

Language selection

Procedure for selecting the operating language of the AirCon Service Center.

Entering company data

Instructions for entering company-specific data for service logs.

Entering the date and time

Procedure for setting the date and time for the AirCon Service Center.

Editing default values

How to adjust preset default parameters for service tasks.

Putting in the containers for oil and UV additive

Guide to installing oil and UV additive containers.

Entering the container size (only for VAS 6381B)

How to input container sizes for oil and UV additive.

Filling up the internal refrigerant container

Instructions for filling the internal refrigerant vessel.

Operation

Shutdown in case of repair, emergencies and malfunctions

Procedure for safely shutting down the unit in various situations.

Short selection

Overview of the fully automatic air conditioning service process.

User codes

Information on protecting the unit with personal user codes.

Creating user codes

Step-by-step guide to creating user codes for access control.

Entering a user code

How to enter a user code to enable the station.

Creating a personal database

Guide to creating a database of customer-specific vehicles.

Transferring the consumption of refrigerant onto a USB stick

How to save and transfer operational data to a USB stick.

Reports after the year has changed

Instructions for transferring annual data after a year change.

Manual reports

Procedure for manually transferring monthly or annual reports.

Showing the refrigerant consumption on the display

How to view refrigerant consumption data on the unit's display.

Air conditioning system test without refrigerant service

Procedure for testing the A/C system without refrigerant recovery.

Free selection

Step-by-step A/C servicing with optional procedures and data entry.

Extraction process

Detailed steps for the refrigerant extraction and recycling phase.

Vacuum process

Procedure for evacuating the system, including leak testing.

Filling process

Steps for filling with fresh oil, UV additive, and refrigerant.

Selecting connections

How to select connections based on the vehicle's A/C system.

After the completion of the air conditioning service

Final steps after completing A/C service, including hose disconnection.

Flushing the air conditioning system

Guide to flushing the A/C system with fresh refrigerant.

Service tasks

Leak test

Procedure for performing annual leak detection on the AirCon Service Center.

Calibrating the oil scales (only VAS 6381B)

Steps to calibrate oil and UV additive scales for accurate measurement.

Changing the dryer filter

Instructions for replacing the dryer filter, including O-ring replacement.

Filter maintenance

Procedures for filter maintenance and resetting service messages.

Calibrating the pressure transducer

Guide to calibrating the pressure transducer for accurate readings.

Changing the vacuum pump oil

Detailed steps for changing the vacuum pump oil.

Meter readings

How to access and interpret various meter readings from the unit.

Filling level correction for longer service hoses

Adjusting filling quantities based on service hose length.

Replacing the printer paper

Instructions for replacing the printer paper roll.

Updating the software via USB

Procedure for updating the unit's software and database via USB.

Manual discharge of non-condensing gases

Procedure for manually discharging non-condensing gases.

Cleaning and maintenance

Disposal

Disposing of used fluids

Guidelines for the proper disposal of used fluids.

Disposing of packaging material

Instructions for disposing of cardboard and plastic packaging.

Disposal of the old unit

Procedures for disposing of the old AirCon Service Center unit.

What to do, when?

Technical data

Flow chart

Diagram illustrating the operational flow of the AirCon Service Center.

Key

List of components and their descriptions used in the technical diagrams.

Electrical circuit diagram

Schematic diagram of the electrical components and connections.

Related product manuals