ASC 6300 G LE, ASC 6400 G LE
EN
A/C service unit
Operating manual.......................................................3
FR
Poste de service climatisation
Manuel d’utilisation................................................... 51
DE
Klimaservicegerät
Bedienungsanleitung............................................... 101
RU
Станция по обслуживанию кондиционеров
Инструкция по эксплуатации....................................151
ES
Estación de mantenimiento de aire
acondicionado
Instrucciones de uso................................................201

Table of Contents

Questions and Answers

  • K
    Kurt WeberSep 16, 2025
    What does Error G1 on Waeco ASC 6300 G LE Service Equipment mean and how to fix it?
    • S
      skirkSep 16, 2025
      Error G1 means that a connection to the analysis module could not be made. Check the connections and see if the LEDs on the module are activated.
  • M
    Michael StanleyAug 25, 2025
    What should I do if my Waeco ASC 6300 G LE Service Equipment displays 'Not enough vacuum! Carry on?'?
    • T
      Tanya NguyenAug 25, 2025
      This message appears during the vacuum process if the pressure in the air conditioning system after 8 min is still more than 50 mbar. Check the air conditioning system or the connections between it and the A/C service unit for leaks.
  • G
    gwashingtonAug 25, 2025
    What does it mean when my Waeco ASC 6300 G LE displays 'A/C system leakage! Carry on?'?
    • G
      Gabriel TurnerAug 26, 2025
      This message appears at the end of the vacuum process. It means the air conditioning system shows a vacuum loss of more than 120 mbar during the checking time. Check the air conditioning system or the connections between it and the A/C service unit for leaks.
  • H
    Hannah DavisAug 26, 2025
    How to fix Error 52 on Waeco ASC 6300 G LE?
    • C
      Christina LozanoAug 27, 2025
      Error 52 means that no USB flash drive was found or recognised. Insert the USB flash drive and ensure that it has been formatted with the FAT32 file system.
  • M
    Mrs. Sheila BradleySep 18, 2025
    What could cause Error 00001 on Waeco ASC 6300 G LE Service Equipment?
    • C
      courtney85Sep 18, 2025
      Error 00001 indicates that the readings are unstable. Keep possible electrical sources of interference, such as mobile phones or welding equipment, away from the device.
  • K
    karenthompsonSep 23, 2025
    What to do if Waeco ASC 6300 G LE Service Equipment displays Error 00001?
    • E
      emma19Sep 23, 2025
      Error 00001 indicates that the refrigerant sample has a very high content of air or the amount of refrigerant was too low for testing. Ensure that there is enough refrigerant pressure and that all the hoses are connected, not kinked, and free of oil.
  • S
    Scott LyonsSep 8, 2025
    What does Error 03 mean on Waeco ASC 6300 G LE and how to fix it?
    • S
      steven15Sep 8, 2025
      Error 03 means that no data is coming from the refrigerant scale. Check the scale.
  • A
    Ashley ThomasSep 9, 2025
    How to solve Error 04 on Waeco ASC 6300 G LE Service Equipment?
    • C
      Christopher RuizSep 9, 2025
      Error 04 indicates that it is not possible to lower the pressure when flushing takes place. Check the air conditioner and connections for leaks, constrictions, and ice build-up. Also, check the pressure transducer calibration.
  • R
    Robert BaldwinSep 3, 2025
    What to check if Waeco ASC 6300 G LE Service Equipment shows 'External tank empty or closed valve. Check!'?
    • J
      Jon FisherSep 3, 2025
      This message appears at the start or during the filling of the internal refrigerant container if the set refrigerant quantity cannot be attained. Check if the external refrigerant container still contains enough refrigerant or if the valves of the external refrigerant container are open.
  • C
    Christine KingSep 1, 2025
    What does it mean when my Waeco ASC 6300 G LE displays 'Not enough oil. Add!'?
    • J
      Jason HortonSep 1, 2025
      This message appears during the filling process if there is not enough fresh oil in the container to finish the process. Top up the fresh oil container with a suitable oil type.

Summary

WAECO ASC 6300;6400 G LE Manual Overview

Manual Structure, Language Options, and Safety Guidelines

Introduces the manual, lists languages, and highlights safety guidelines.

Intended Use, Accessories, and Support

Specifies unit applications, optional items, and contact information.

Unit Description and Initial Configuration

Technical Features, Components, and Safety Devices

Describes unit features, identifies parts, and explains safety mechanisms.

Initial Setup: Power, Refrigerant, Language, and Settings

Guides through powering on, selecting refrigerant, language, and configuring basic settings.

Operating Modes and Service Functions

Basic Operation, Shutdown, System Testing, and User Management

Covers operation, shutdown, testing, and user access control.

Automated, Manual, and Flushing Service Modes

Explains automated, manual, and flushing service modes.

Maintenance Tasks and Data Handling

Covers filter replacement, calibration, updates, and data export.

Troubleshooting, Disposal, and Technical Data

Diagnosing and Resolving Operational Issues

Guidance for diagnosing and resolving problems, errors, and warnings.

Environmental Disposal and Technical Specifications

Procedures for disposal and detailed technical data for both unit models.

System Diagrams and Circuit Schematics

Flowcharts and electrical schematics illustrating unit operation.

Waeco ASC 6300 G LE Specifications

General IconGeneral
BrandWaeco
ModelASC 6300 G LE
CategoryService Equipment
LanguageEnglish