What should I do if my Waeco Service Equipment shows 'Change the equipment drier filter! Go on?'?
R
Robert ChambersSep 5, 2025
This message appears when you switch on the AirConServiceCenter. Change the internal filter as soon as possible. To skip this message, press ENTER for 3 seconds.
M
Michelle ColemanAug 25, 2025
What does 'Printer not in line! Carry on?' mean on my Waeco Service Equipment and how to fix it?
J
Jacqueline WhiteAug 25, 2025
This message indicates a printer fault. Check if there is paper in the printer, ensure the printer is switched on (the yellow LED should be lit), and verify that the cover is closed properly.
J
jose16Aug 25, 2025
What to do if my Waeco Service Equipment displays 'Warning! Internal vessel full!'?
K
Kara ThompsonAug 26, 2025
This message indicates that the internal refrigerant container is too full to hold the quantity to be extracted. You should drain the internal refrigerant container in the proper manner.
C
craig73Aug 26, 2025
What does 'A/C system leakage! Carry on?' mean on Waeco Service Equipment and what to do?
K
Kayla BraunAug 26, 2025
This message appears at the end of the vacuum process, indicating that the air conditioning system shows a vacuum loss of more than 120 mbar during the checking time. Check the air conditioning system and the connections between it and the AirConServiceCenter for leaks.
K
Kelly PadillaAug 27, 2025
What to do if Waeco Service Equipment displays 'Not enough vacuum! Carry on?'?
L
Lisa DayAug 27, 2025
This message appears during the vacuum process if the pressure in the air conditioning system after 8 minutes is still more than 50 mbar. Check the air conditioning system or the connections between it and the AirConServiceCenter for leaks.
N
Nicholas JohnsonSep 13, 2025
What does 'External tank empty or closed valve. Check!' mean on my Waeco Service Equipment?
R
Ryan WilliamsSep 13, 2025
This message appears at the start or during the filling of the internal refrigerant container if the set refrigerant quantity cannot be attained. Check if the external refrigerant container still contains enough refrigerant or if the valves of the external refrigerant container are open.
C
Crystal ArmstrongSep 12, 2025
What does 'Quantity too large. Fill internal vessel!' mean on my Waeco Service Equipment?
A
Amanda AlexanderSep 12, 2025
This message appears during the process input if there is not enough refrigerant in the internal container to complete the process. Fill the refrigerant container.
N
Nicole LewisSep 12, 2025
What does 'Max. filling time exceeded! Carry on?' mean on my Waeco Service Equipment?
M
Monica FosterSep 12, 2025
This message appears during the filling process if the set amount of refrigerant cannot be filled. Check that AirConServiceCenter connections are not blocked.
P
Peter BrownSep 4, 2025
Why does my Waeco Service Equipment show 'Warning! Pressure inside the A/C system!'?
C
Christopher DoyleSep 4, 2025
This message appears during the vacuum process, indicating there is pressure in the air conditioning system. No action is required, as the process continues automatically.
A
Angela Hall MDSep 2, 2025
What to do if my Waeco Service Equipment displays 'Drained oil glass emptying!'?
N
Nathaniel WilsonSep 2, 2025
This message appears during the extraction or recycling process if there is more than 150 ml of used oil in the container. Dispose of the content of the used oil container in an environmentally responsible manner.