EasyManua.ls Logo

Waeco AirConServiceCenter ASC1000G User Manual

Waeco AirConServiceCenter ASC1000G
300 pages
Go to English
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
AirConServiceCenter
ASC1000G/ASC2000G/ASC3000G
DE 3 Klimaservicegerät
Bedienungsanleitung
EN 62 Air conditioning service unit
Operating manual
ES 120 Estación de mantenimiento de aire acondicionado
Instrucciones de uso
FR 180 Poste de service climatisation
Notice d'utilisation
RU 240 Станция по обслуживанию кондиционеров
Инструкция по эксплуатации

Table of Contents

Questions and Answers:

Waeco AirConServiceCenter ASC1000G Specifications

General IconGeneral
ModelASC1000G
CategoryService Equipment
ManufacturerWaeco
Refrigerant Tank Capacity12 kg
Refrigerant Capacity12 kg
CompressorHermetic
Power Supply220-240 V
Voltage220-240 V
Frequency50/60 Hz
Oil ManagementAutomatic
DisplayDigital
TypeAir Conditioning Service Station
Refrigerant TypeR134a
RefrigerantR134a
Operating ModesRecovery, Recycle, Recharge
Weight110 kg

Summary

About This Operating Manual

Hotline Support Information

Contact details for obtaining further information or assistance with the AirCon Service Center.

Explanation of Operating Manual Symbols

Defines the meaning of various graphical symbols used throughout the manual for user guidance.

Safety Guidelines and Precautions

General Safety Instructions

Provides essential guidelines for safe operation and handling of the AirCon Service Center.

AirCon Service Center Specific Warnings

Highlights critical warnings and precautions specific to the operation and environment of the AirCon Service Center unit.

Safety Device Descriptions

Details the built-in safety mechanisms, such as pressure monitors and relief valves, designed to protect the unit and user.

Scope of Delivery Details

ASC1000G Scope of Delivery

Lists the standard accessories and components included with the ASC1000G model.

ASC2000G Scope of Delivery

Lists the standard accessories and components included with the ASC2000G model.

ASC3000G Scope of Delivery

Lists the standard accessories and components included with the ASC3000G model.

Optional Extras Available

Proper Use and Intended Application

Usage Guidelines and Restrictions

Outlines the correct usage of the AirCon Service Center and any limitations on its application.

AirCon Service Center Overview

Front Panel Component Identification

Identifies and explains the components located on the front of the AirCon Service Center unit.

Rear Panel Component Identification

Identifies and explains the components located on the rear of the AirCon Service Center unit.

Initial Startup Procedures

Setting Up and Powering On

Instructions for physically setting up the unit and powering it on for the first time.

Standby Menu Information Display

Describes the information displayed in the standby menu and its various components.

Language Selection Process

Step-by-step guide to selecting the preferred language for the device interface.

Entering Company Data

Procedure for inputting company-specific information that will be printed on service logs.

Setting Date and Time

Instructions for setting the current date and time for accurate record-keeping and log entries.

Editing Default Values

Guide on how to modify pre-set default values for various service tasks to customize operation.

Inserting Oil and UV Additive Containers

Details on how to correctly insert the oil and UV additive containers into their designated slots.

Entering Container Size

Procedure for specifying the size of the oil and UV additive containers used for accurate measurement.

Filling Internal Refrigerant Container

Instructions for filling the unit's internal refrigerant container from an external source.

Operation of the AirCon Service Center

Short Selection Process

Details the fully automatic air conditioning service process using the 'Short selection' menu.

User Code Management

Enables the creation, entry, and management of personal user codes for system access control.

Creating User Codes

Steps to create personal user codes for authorized access and operation of the AirCon Service Center.

Entering User Codes

Procedure for entering an existing user code to enable the AirCon Service Center for operation.

Creating Personal Vehicle Database

Guide on how to create a custom database of vehicles and their refrigerant filling quantities for quick selection.

Transferring Data to USB Stick

Instructions for saving service data, reports, and databases onto a USB flash drive.

Generating Manual Reports

How to manually generate monthly or annual reports and transfer them to a USB stick for record-keeping.

Displaying Refrigerant Consumption Data

Methods for viewing refrigerant filled and extracted data, either monthly or annually, on the unit's display.

AC System Test Without Refrigerant Service

Procedure for testing the vehicle's AC system without extracting refrigerant, focusing on system integrity.

Free Selection Process

Enables step-by-step execution of individual air conditioning servicing processes, allowing customization.

Recovery Phase Operations

Details the steps for refrigerant recovery, recycling, and pressure increase testing within the AC service.

Vacuum Process Operations

Explains the process of system evacuation, leak testing, and vacuum checks to prepare for filling.

Filling Process Operations

Instructions for filling the system with fresh oil, UV additive, and refrigerant according to specifications.

Selecting AC Connections

Guides on selecting the correct connections (HP/LP, HP, or LP) based on the vehicle's AC system configuration.

Concluding AC Service

Steps to follow after completing an air conditioning service operation, including disconnection and final checks.

Flushing the Air Conditioning System

Procedure for flushing the vehicle's AC system with fresh refrigerant to remove contaminants and residues.

Service Tasks and Maintenance

Calibrating Oil Scales

Steps to calibrate the scales used for accurately measuring oil and UV additive quantities.

Changing the Dryer Filter

Instructions for replacing the dryer filter component of the AirCon Service Center to maintain system performance.

Filter Maintenance and Reset Procedures

Procedure for resetting service messages and counters after filter replacement or maintenance.

Calibrating the Pressure Transducer

Guide on calibrating the pressure transducer for accurate pressure measurements during AC service.

Changing the Vacuum Pump Oil

Detailed steps for safely draining and refilling the vacuum pump oil to ensure optimal performance.

Meter Readings and Counter Access

Information on accessing and interpreting various counter readings and service logs stored in the device.

Adjusting Filling Quantity for Service Hoses

Instructions for adjusting filling quantities when using service hoses of different lengths for accurate measurements.

Replacing Printer Paper

Procedure for replacing the paper roll in the integrated printer of the AirCon Service Center.

Updating Software via USB

Steps for updating the AirCon Service Center's software and database using a USB stick.

Cleaning and General Maintenance

Guidelines for routine cleaning of the unit's exterior and checking service hoses for any damage.

Disposal Procedures

Disposing of Used Fluids

Information on the proper and environmentally responsible disposal of hazardous used fluids from the system.

Disposing of Packaging Material

Guidance on how to dispose of the unit's packaging materials, separating recyclable components.

Scrapping the Old Unit

Instructions for decommissioning and environmentally responsible disposal of the AirCon Service Center unit.

Troubleshooting Common Issues

Technical Specifications

Related product manuals