Walchem WTCW100 Series User Manual

Default Icon
31 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Five Boynton Road Hopping Brook Park Holliston, MA 01746 USA
TEL: 508-429-1110 WEB: www.walchem.com
WCT/WBLW100 Series
Cooling Tower and Boiler Controller
Instruction Manual
Question and Answer IconNeed help?

Do you have a question about the Walchem WTCW100 Series and is the answer not in the manual?

Walchem WTCW100 Series Specifications

General IconGeneral
ModelWTCW100 Series
TypeController
DisplayLCD
OutputRelay, Analog
Communication ProtocolModbus RTU
Temperature Range (Operating)0°C to 50°C
Temperature Range (Storage)-20°C to 70°C
EnclosureNEMA 4X
Sensor InputspH, ORP, Conductivity, Temperature
Analog InputsUp to 4 inputs; 4-20 mA, isolated

Summary

Unpacking and Installation

Mounting the Electronic Enclosure

Guidelines for securely wall-mounting the controller enclosure at eye level on a vibration-free surface.

Installation

General installation advice for the controller and metering pumps, including plumbing for cooling towers and boilers.

Electrical Installation

Operation

Relay Any Control Mode Settings

General settings applicable to any relay control mode, including HOA, timeouts, and interlocks.

Relay On/Off Control Mode Settings

Configuration for On/Off relay control, including set point, deadband, and duty cycle.

Relay Flow Timer Control Mode Settings

Settings for flow timer control mode, including feed duration and accumulated volume.

Relay Bleed and Feed Control Mode Settings

Settings for bleed and feed control, available when HVAC modes are enabled.

Relay Bleed then Feed Control Mode Settings

Settings for bleed then feed control, available when HVAC modes are enabled.

Relay Percent Timer Control Mode Settings

Settings for percent timer control mode, including sample period and feed percentage.

Relay Biocide Timer Control Mode Settings

Settings for biocide timer control, including event programming, repetition, and special conditions.

Relay Alarm Mode Settings

Configuration for relay alarm mode, selecting alarm conditions and output behavior.

Relay Time Proportional Control Mode Settings

Settings for time proportional control, including set point, proportional band, and sample period.

Relay Intermittent Sampling Control Mode Settings

Settings for intermittent sampling, including set point, proportional band, and trap sample options.

Relay Pulse Proportional Control Mode Settings

Settings for pulse proportional control, including set point, minimum/maximum output, and rate.

Maintenance

Troubleshooting

Calibration Failure

Lists possible causes and corrective actions for calibration failures in contacting and electrodeless conductivity sensors.

Alarm Messages

Explains various alarm messages, their possible causes, and corrective actions.