Do you have a question about the Water Right Sanitizer Plus and is the answer not in the manual?
Brand | Water Right |
---|---|
Model | Sanitizer Plus |
Category | Water System |
Language | English |
Displays the current time on the unit. Unit defaults to this screen after a reset.
Displays the current flow rate of water passing through the unit.
Displays the unit's remaining capacity in gallons.
Displays the number of days remaining until the next scheduled regeneration.
Displays a scrolling dealer name and phone number.
Indicates the valve controller is unlocked, granting access to advanced programming features.
Indicates the valve controller is locked, preventing accidental access to advanced settings.
Allows setting the hour for the unit's clock using + or - buttons.
Allows setting the minutes for the unit's clock using + or - buttons.
Allows setting the current day of the week using + or - buttons.
Displays the time remaining in the current regeneration cycle.
Displays time remaining in current cycle, relevant if a chlorine generator is connected.
Sets the water hardness level in grains.
Sets the number of days between automatic regenerations.
Sets the hour of the day for regeneration.
Sets the minutes for the regeneration time.
Turns the alarm buzzer ON or OFF for regeneration or error alerts.
Sets the display backlight operation, including an auto-off feature.
Features for accessing and setting the dealer name and phone number.
Turns the service alarm ON or OFF based on gallons used.
Sets the number of gallons before the service alarm triggers.
Displays the remaining gallons before the service alarm triggers.
Turns the service alarm ON or OFF based on time in years.
Sets the number of years before the service alarm triggers.
Displays the remaining time before the service alarm triggers.
Selects between SOFTENING or FILTERING modes for the unit.
Sets the system's grains of capacity for water softening.
Sets the gallon capacity calculation method (AUTO, OFF, or by specific gallons).
Sets the percentage of capacity overrun that triggers a double regeneration.
Sets the first cycle position related to the fill process.
Sets the amount of salt (in pounds) delivered during the fill cycle.
Sets the second cycle position used for delivering soft water.
Sets the time window for salt to dissolve and achieve proper brine strength.
Sets the third cycle position, typically for backwashing the media.
Sets the duration for the backwash cycle.
Sets the fourth cycle position for regenerant draw.
Sets the duration for the regenerant draw process.
Turns chlorine generator ON/OFF or adjusts chlorine production level.
Sets the fifth cycle position for rinsing.
Sets the duration for the final rapid rinse cycle.
Sets the end cycle position to trigger the end of regeneration.
Selects the valve type and meter size (e.g., 1", 1.0T).
Sets regen time control to Delayed, Delayed+Immediate, or Immediate.
Sets the first MAV drive control mode (e.g., System Controller, Separate Source).
Configures auxiliary input behavior (e.g., Immediate regen, Hold, Alarm).
Sets Relay 1 trigger to OFF if no external devices are used.
Sets Relay 1 to trigger for a specified period during regeneration.
Sets the delay time before Relay 1 initially energizes after regen starts.
Sets the duration Relay 1 remains energized after its setpoint.
Sets Relay 1 to trigger after a specified number of gallons are expended.
Sets the number of gallons to be expended before Relay 1 energizes.
Sets the duration Relay 1 remains energized after the gallon setpoint.
Sets Relay 1 to trigger based on gallons expended during service and regen.
Sets the gallons to be expended before Relay 1 energizes during regen.
Sets the duration Relay 1 remains energized after the regen gallon setpoint.
Sets Relay 1 to trigger when the unit is in an error mode.
Sets Relay 1 to trigger when flow is detected by the control.
Sets Relay 1 to generate a dry-contact signal output.
Sets the meter pulses per gallon (PPG) for the pulse trigger.
Displays the number of days that have passed since the last regeneration.
Displays the total gallons of water processed since the last regeneration.
Displays the calculated reserve capacity of the water softening system.
Displays past 90 days of water usage history, with indicators for regen, manual regen, or errors.
Displays gallon usage for specific hours within the last 90 days.
Displays a history of the last 10 tank transfers, including type and gallons.
Displays peak flow rate history over the last 7 days.
Displays the total gallons used by Meter 1 since the last reset.
Displays the total number of days the unit has been in service.
Displays the total number of regenerations the unit has performed since startup.
Displays brine concentration history for the last 50 regenerations.
Displays voltage consumed and brine draw time for the last 50 regenerations.
Displays the total number of errors recorded from all brine cycles.
Displays MAV drive time history for an active MAV 1 output.
Displays the current software version of the control unit.
Displays total gallons used by Meter 1 since startup (non-resettable).
Displays total days unit has been in service (non-resettable).
Displays total regenerations since startup (non-resettable).
Displays the last ten valve errors that occurred.
Displays the error log, including motor position during the error.
Valve not sensing valve movement with motor energized.
Valve unable to find next cycle position (stalled).
Valve unable to find next cycle position.
Valve unable to find Home position.
MAV 1 motor ran too long, unable to find proper park position.
MAV 1 motor ran too short, unable to find proper park position.
Control detected an invalid motor state.
MAV 2 motor ran too long, unable to find proper park position.
MAV 2 motor ran too short (stalled).
Control detected an invalid regeneration cycle step.
Leak detected by the control system.
Check sum error for operational data and status section of EEPROM memory.
Check sum error for programming section of EEPROM memory.
Check sum error for diagnostic section of EEPROM memory.
Check sum error for history section of EEPROM memory.
Check sum error for contact screen section of EEPROM memory.
Control operation affected by corrupted data in RAM memory.
Control operation affected by corrupted data in diagnostic RAM memory.
Configuration file downloaded does not match software revision.