Questions and Answers

  • S
    srobbinsAug 16, 2025
    What to do if display does not indicate that water is flowing in Water Right Sanitizer Plus ASP2-1054 Water Dispenser?
    • J
      Jessica CochranAug 17, 2025
      If the display on your Water Right Water Dispenser doesn't indicate water flow, first ensure the bypass handles are correctly positioned for service. Then, check if the meter is properly connected to the PC board's meter connection. Also, verify that the meter cable wires are securely installed into the three-pin connector labeled 'METER'. Finally, examine the meter for any obstructions or rotation issues. If these steps don't resolve the issue, the meter or PC board might be defective and require replacement.
  • G
    Gerald AguilarAug 19, 2025
    Why does Water Right Water Dispenser control valve regenerates at wrong time of day?
    • M
      michael62Aug 19, 2025
      If your Water Right Water Dispenser control valve regenerates at the wrong time, it might be due to a power outage, which requires resetting the time of day. Also, verify that the time of day and regeneration time are set correctly. Ensure the control valve is not set to 'on 0' or 'NORMAL + on 0'; it should be set to 'NORMAL' for delayed regeneration.
  • B
    Bryan ParkAug 22, 2025
    What to do if Water Right Sanitizer Plus ASP2-1054 delivers hard or untreated water?
    • M
      marquezleahAug 22, 2025
      If you have hard or untreated water being delivered by your Water Right Water Dispenser, the bypass valve may be open or faulty, requiring you to fully close or replace it. High water usage can exhaust the media, so check program settings or diagnostics for abnormal usage. Also, inspect the meter for proper registration and any obstructions. Ensure there's an adequate level of regenerant in the tank and that the control is drawing it in correctly. Check the refill setting and flow control for any issues. If problems persist, the seal/stack assembly may be damaged, the media bed fouled, or the control valve and piston types mismatched, all of which would require replacement.
  • V
    Vincent WattsAug 25, 2025
    Why Water Right Sanitizer Plus ASP2-1054 doesn't regenerate automatically unless the buttons are pressed?
    • V
      vriosAug 26, 2025
      If your Water Right Water Dispenser control valve does not regenerate automatically but does when you depress and hold the correct buttons, ensure the bypass valve is not in the bypass position by turning the bypass handles to the service position. Check that the meter is connected to the meter connection on the PC board and that the meter cable wires are securely installed into the three pin connector labeled METER. Remove the meter to check for rotation or foreign material that may be causing a restricted or stalled meter turbine. Verify the programming is correct. If these steps do not solve the problem, the meter or PC board may be defective and require replacement.
  • N
    Nathan BakerAug 27, 2025
    How to fix no display on Water Right Water Dispenser PC board?
    • S
      Selena AustinAug 28, 2025
      If the display on the PC board of your Water Right Water Dispenser is blank, verify that the electric outlet has power and use a working outlet if necessary. Ensure the control valve power adapter is plugged into the outlet and connected to the PC board. Confirm the power supply is delivering the correct voltage to the PC board. If these steps don't resolve the issue, the power adapter or PC board may be defective and require replacement.
  • L
    Lisa RodriguezAug 30, 2025
    Why time of day flashes on and off on Water Right Sanitizer Plus ASP2-1054?
    • E
      Erika Jones MDAug 30, 2025
      If the time of day flashes on and off on your Water Right Water Dispenser, it is likely due to a power outage. Reset the time of day. If your PC board has a battery backup, the battery may be depleted.
  • M
    Mark CastroSep 2, 2025
    Why Water Right Sanitizer Plus ASP2-1054 control valve uses too much regenerant?
    • A
      Anna BrownSep 2, 2025
      If your Water Right Water Dispenser control valve uses too much regenerant, examine the refill setting and program settings to ensure they are specific to your water quality and application needs. Also, check for leaking fixtures or an undersized system that may be causing frequent regenerations.
  • M
    Monique GarrisonSep 4, 2025
    How to fix PC board does not display correct time of day on Water Right Sanitizer Plus ASP2-1054 Water Dispenser?
    • P
      Paul Weber MDSep 5, 2025
      If the PC board on your Water Right Water Dispenser does not display the correct time of day, ensure the power adapter is plugged into an uninterrupted outlet, not one controlled by a light switch. Reset any tripped breaker switches or GFI switches. After a power outage, reset the time of day; if the PC board has a battery backup, the battery may be depleted. If the problem persists, the PC board may be defective and require replacement.
  • T
    Todd LongSep 7, 2025
    What causes excessive water in regenerant tank of Water Right Sanitizer Plus ASP2-1054?
    • G
      Gabriel BeckSep 7, 2025
      If there's excessive water in the regenerant tank of your Water Right Water Dispenser, start by checking the refill setting in the program. Then, inspect the injector for clogs and clean or replace it. Ensure the drive cap assembly is properly tightened. Also, check the drain line for restrictions or kinks and clear them. Finally, inspect the backwash flow controller for clogs and replace the refill flow controller if it's missing. If these steps don't resolve the issue, the seal/stack assembly may be damaged and require replacement.
  • G
    Gina BurchSep 10, 2025
    What to do if Water Right Sanitizer Plus ASP2-1054 control valve does not regenerate automatically when buttons are depressed?
    • G
      Gregory BowersSep 12, 2025
      If your Water Right Water Dispenser control valve does not regenerate automatically when the correct buttons are depressed and held, the drive gear or drive cap assembly could be broken, requiring replacement. Alternatively, the piston rod may be broken and also require replacement. A defective PC board could also be the cause.

Summary

PRE-INSTALLATION INSTRUCTIONS FOR DEALERS

BYPASS VALVE OPERATION

Understanding Bypass Valve Positions

Explains the four positions of the bypass valve: normal, bypass, diagnostic, and shut off.

INSTALLATION PROCEDURES

General Installation Warnings and Site Requirements

Covers general warnings, lubrication, site requirements, and plumbing considerations.

START-UP INSTRUCTIONS

Initial Setup and Regeneration Sequence

Guides through initial water filling, system regeneration sequence, and leak checks.

PROGRAMMING PROCEDURES

Setting the Time of Day

Instructions for setting the current hour, minutes, and day of the week.

Configuring Hardness and Regeneration Settings

Steps to set water hardness, days between regeneration, and other programming parameters.

OPERATING DISPLAYS AND INSTRUCTIONS

REGENERATION MODES AND POWER MANAGEMENT

Understanding Regeneration Processes (Mode, Manual)

Describes automatic regeneration, manual regeneration initiation, and process steps.

Power Loss and Battery Replacement Procedures

Covers system behavior during power outages and how to replace the control valve battery.

SYSTEM STATUS AND MAINTENANCE

TROUBLESHOOTING GUIDE

Display and Power Related Issues

Addresses problems with no display, incorrect time, and water flow indication.

Regeneration Timing and Time of Day Errors

Troubleshooting for incorrect regeneration times and flashing time of day indicators.

TROUBLESHOOTING COMMON PROBLEMS

TROUBLESHOOTING CONTROL VALVE ISSUES

Motor Positioning and Stalling Errors (E1, E2)

Diagnosing and resolving motor position errors and stalling conditions.

TROUBLESHOOTING MOTOR AND VALVE ERRORS

Motor Timing and Alternating Valve Errors (E3, E4, E1006)

Addresses motor timing errors, alternating valve issues, and stalled motor conditions.

TROUBLESHOOTING SYSTEM ERROR CODES

Motor Stalling and Invalid State Errors (E1007, E109)

Troubleshooting for motor stalling, invalid motor states, and regeneration cycle errors.