Questions and Answers

  • T
    Tara FisherJul 30, 2025
    How to fix a Water Right FFE-1054-M that fails to regenerate?
    • S
      Samantha MartinezJul 30, 2025
      If your Water Right Water Dispenser fails to regenerate, it could be due to a couple of reasons. First, ensure that the unit has permanent electrical service by checking the fuse, plug, pull chain, or switch. Second, verify that the timer is programmed correctly, and reset it if needed.
  • B
    Bobby YoungAug 5, 2025
    Why is my Water Right Water Dispenser using too much salt?
    • K
      Kathy AlvarezAug 5, 2025
      If your Water Right Water Dispenser is using too much salt, start by checking the salt usage and salt setting. Also, review the programming and reset if needed.
  • M
    Ms. Jennifer RichardsonAug 9, 2025
    What to do if my Water Right Water Dispenser has loss of water pressure?
    • J
      Joy RobinsonAug 9, 2025
      If you're experiencing a loss of water pressure with your Water Right Water Dispenser, it could be due to air in the water system. Ensure that your well system has a proper air eliminator control and check for a dry well condition. Also, verify that the drain line flow control is sized correctly.
  • S
    Suzanne HernandezAug 14, 2025
    How to remove iron from conditioned water from Water Right FFE-1054-M Water Dispenser?
    • J
      Jason GomezAug 14, 2025
      If you notice iron in the conditioned water from your Water Right Water Dispenser, it could be due to iron buildup. Clean the line to the water conditioner. Additionally, clean the control, add resin cleaner to the resin bed, and increase the frequency of regeneration.
  • S
    Sophia AllenAug 19, 2025
    What causes loss of resin through drain line in Water Right Water Dispenser?
    • S
      Samuel HardyAug 19, 2025
      If you're experiencing a loss of resin through the drain line of your Water Right Water Dispenser, it might be due to a fouled resin bed. Check the backwash, brine draw, and brine tank fill. Increase the frequency of regeneration and backwash time. If the iron content exceeds recommended parameters, consider adding iron removal from a filter or system.
  • A
    Amanda McbrideOct 24, 2025
    Why is my Water Right Water Dispenser delivering hard water?
    • W
      Wendy VillarrealOct 24, 2025
      If your Water Right Water Dispenser is delivering hard water, several factors could be the cause. First, make sure the by-pass valve is closed. Check the salt level in the brine tank and ensure it's above the water level. Inspect and clean the injectors and screen for any blockages. Insufficient water flowing into the brine tank can also be a problem; check the brine tank fill time and clean the brine line if it's plugged. If you have a hot water tank, repeated flushings might be necessary. Also, make sure that the unit is plumbed correctly and the line pressure is at least 20psi. Retest your water hardness and change the settings accordingly. Check for a jammed flow meter or disconnected cable, and reprogram the control to the proper regeneration type, inlet water hardness, capacity, or f...

Summary

Important Safety Information

Instructions Before Using

Specifications

Feedwater

Details on water quality, pressure, and temperature requirements for the softener's operation.

Power

Electrical specifications including voltage, frequency, and power consumption for the unit.

Installation

Guidelines for the physical placement and environmental conditions for the softener installation.

Salt Capacity

Information on the maximum amount of salt the softener's brine tank can hold.

Setup

Unpacking and Inspection

Instructions for checking system components for damage or missing parts upon receipt.

Where to Install the Softener

Key considerations and recommended locations for installing the water softening system.

Hardness Setting

Guidance on determining and setting the water hardness level for optimal system performance.

Installation

Control Start-up Procedures

Programming

Steps for setting up the control unit, including time of day and metered/time clock settings.

Water softener start-up

Softener Operation

Service

Explanation of the normal operating mode where the softener removes hardness minerals.

Backwash Position

Description of the cycle that flushes the resin bed and removes debris.

Brine Draw; Slow Rinse Position

Process of drawing brine and rinsing the resin to replace hardness ions with sodium.

Fast Rinse Position

Cycle that flushes remaining brine from the tank after regeneration.

Brine Fill

Process where water fills the brine tank and dissolves salt for the next regeneration.

Softener Anatomy

flow diagrams

Service position

Diagram illustrating water flow during the normal service operation of the softener.

Pre Rinse 5 minutes

Diagram showing water flow during the pre-rinse cycle of the softener.

Backwash 10 minutes

Diagram illustrating water flow during the backwash cycle to clean the resin bed.

Brine Draw 15-20 of 50 minute cycle

Diagram depicting the flow of brine through the resin tank for regeneration.

Slow Rinse balance of 50 minute cycle

Diagram showing water flow during the slow rinse phase after brine draw.

Rapid Rinse 10 minutes

Diagram illustrating water flow during the rapid rinse cycle to remove residual brine.

Settling rinse 5 minutes

Diagram showing water flow during the settling rinse phase of the regeneration cycle.

Regenerant tank refill Adjustable4-24 minutes

Diagram illustrating water flow during the refill of the brine tank after regeneration.

Service

Cleaning Iron Out of the Water Softening System

Procedure for cleaning mineral buildup, particularly iron, from the softener's resin bed.

Checking for a Salt Bridge

How to identify and understand the causes of a hardened salt crust in the brine tank.

Breaking a Salt Bridge

Methods for physically breaking up a salt bridge to restore brine tank functionality.

Cleaning the Injector and Screen

Detailed steps for disassembling, cleaning, and reassembling the injector and screen.

Troubleshooting

Softener Fails To Regenerate

Common causes and solutions when the softener does not complete its regeneration cycle.

Softener Delivers Hard Water

Troubleshooting steps for when the unit is not effectively softening water.

Unit Uses Too Much Salt

Identifying reasons for excessive salt consumption by the water softener.

Loss of Water Pressure

Diagnosing and resolving issues related to reduced water pressure after softener installation.

Loss of Resin Through Drain Line

Investigating and fixing problems causing resin to be expelled via the drain line.

Iron in Conditioned Water

Addressing the issue of iron contamination in the softened water output.

Excessive Water in Brine Tank

Troubleshooting steps for an overfilled brine tank.

Salt Water in Service Line

Diagnosing and fixing the problem of salt entering the softened water supply.

Softener Fails to Draw Brine

Solutions for when the softener is unable to draw brine from the salt tank.

Drain Flows Continuously

Identifying causes and solutions for continuous water flow from the drain line.

Loss of capacity

Addressing issues leading to a reduced softening capacity of the unit.

parts diagrams

meter assembly

Exploded view and part list for the water meter component of the control assembly.

by-pass valve assembly

Exploded view and part list for the bypass valve assembly used with the softener.

control assembly measured water softener

Detailed breakdown of parts for the main control unit of the metered water softener.

control valve assembly time clock parts diagrams

Exploded view and part list for the time clock control valve assembly.

control valve body assembly

Detailed breakdown of parts for the main control valve body.

Water Right FFE-1054-M Specifications

General IconGeneral
BrandWater Right
ModelFFE-1054-M
CategoryWater Dispenser
LanguageEnglish