Master Programming Manual
for Impression, Impression Plus,
and Impression Twin Models
Effective January 2018

Other manuals for Water Right Impression

Question and Answer IconNeed help?

Do you have a question about the Water Right Impression and is the answer not in the manual?

Summary

General Operation Screens

Current Time Display

Shows the current time and day.

Flow Rate Display

Displays the current water flow rate in GPM.

Capacity Remaining Display

Shows the unit's remaining water capacity in gallons.

Days to Regeneration Display

Indicates the number of days until the next regeneration.

Dealer Information Display

Alternates with system displays, showing dealer name and phone.

Set Time Screens

Set Hour and Minute

Adjusts the hour and minute for the unit's clock.

Set Current Day

Sets the current day of the week for the unit.

Typical Regeneration Screens

Regeneration Cycle Time Remaining

Displays the time left in the current regeneration cycle.

Ozone Generator Operation Time

Shows time remaining for ozone generator operation, if connected.

Softener Installer;User Screens

Water Hardness Setting

Configures the water hardness level in grains per gallon.

Days Between Regeneration

Sets the interval in days between automatic regenerations.

Regeneration Time Setting

Defines the specific hour and minute for regeneration cycles.

Backlight Operation

Controls the display backlight, with options for ON or OFF.

Dealer Name and Phone Number

Allows setting and viewing of dealer contact information.

Filter Installer;User Screens

Days Between Regeneration

Sets the interval in days between automatic regenerations.

Regeneration Time Setting

Defines the specific hour and minute for regeneration cycles.

Backlight Operation

Controls the display backlight, with options for ON or OFF.

Dealer Name and Phone Number

Allows setting and viewing of dealer contact information.

Service;OEM SOFTENING Screens

Softening;Filtering Type Selection

Selects between softening and filtering modes for the unit.

Grains of Capacity Setting

Sets the system's capacity in grains of hardness.

Gallon Capacity Calculation

Configures how the unit calculates remaining water capacity.

Double Regeneration Point

Sets the percentage of capacity overrun triggering consecutive regenerations.

Cycle Position Settings

Defines the sequence and type for the first, second, and third cycles.

Softening Time

Sets the duration for the softening phase of regeneration.

Backwash Time

Sets the duration for the backwash phase of regeneration.

Service;OEM SOFTENING Screens (continued)

Additional Cycle Positions

Configures fourth, fifth, and end cycle positions for regeneration.

Draw Time Setting

Sets the draw time for the regeneration cycle.

Service;OEM FILTERING Screens

Filtering Type Selection

Selects between softening and filtering modes for the unit.

Gallons Capacity for Filtering

Sets the capacity in gallons for filtering operations.

Double Regeneration Point (Filtering)

Sets the percentage of capacity overrun triggering consecutive regenerations.

Backwash Cycle Settings

Configures backwash-air time and second/third cycle positions.

Backwash Time Setting

Sets the duration for the backwash phase of regeneration.

Service;OEM FILTERING Screens (continued)

Draw Time Setting (Filtering)

Sets the draw time for the regeneration cycle.

Ozone Generator Configuration

Sets ozone generator options, operation time, and alarm settings.

End Cycle Setting (Filtering)

Configures the final cycle position to end regeneration.

Configuration Screens

Valve Type and Meter Size

Selects the valve type and meter size for unit configuration.

Regen Time Control Setting

Configures how the unit controls regeneration timing.

Pre-Service Rinse Time

Sets the duration for the pre-service rinse cycle.

MAV Drive Control and Auxiliary Input

Configures MAV drive settings and auxiliary input functions.

Relay 1 Configuration

Relay 1 Time Trigger Settings

Configures Relay 1 trigger based on time with setpoint and duration.

Relay 1 Gallons Trigger Settings

Configures Relay 1 trigger based on gallons used with setpoint and duration.

Relay 1 Regen Trigger Settings

Configures Relay 1 trigger based on regeneration gallons with setpoint and duration.

Relay 1 Error Trigger

Configures Relay 1 to trigger when the unit is in an error mode.

Relay 1 Flow Trigger

Configures Relay 1 to trigger when flow is detected.

Relay 1 Pulse Trigger and Setpoint

Configures Relay 1 for pulse trigger and sets meter pulses per gallon.

First Level History Screens

Days Since Last Regeneration

Displays the number of days elapsed since the last regeneration.

Gallons Used Since Last Regeneration

Shows the total gallons consumed since the last regeneration.

Reserve Capacity Display

Displays the calculated reserve water capacity.

Gallon Usage History

Provides historical data on daily water usage and regeneration events.

Tank Transfer History (1.0 T Mode)

Shows recent tank transfer events and gallons used.

Peak Flow Rate History

Displays the peak flow rate recorded over the last seven days.

Total Gallons Used (Meter 1)

Shows total gallons used by Meter 1 since the last reset.

Total Days in Service

Displays the total number of days the unit has been operational.

Total Regenerations Since Startup

Shows the cumulative number of regenerations performed.

Ozone Generator Performance History

Reviews ozone generator performance over the past 50 regenerations.

MAV Drive Time History

Displays drive time history for MAV 1 output.

Second Level History Screens

Software Version

Displays the current software version of the unit.

Total Gallons Used (Meter 1)

Shows total gallons used by Meter 1 since the last reset.

Total Days in Service

Displays the total number of days the unit has been operational.

Total Regenerations Since Startup

Shows the cumulative number of regenerations performed.

Last Ten Valve Errors Recorded

Lists the last ten valve errors that occurred on the unit.

Error Codes and Descriptions

Common Error Code Explanations

Lists common error codes and their descriptions for troubleshooting.

Overview

This document is a Master Programming Manual for Water-Right Impression, Impression Plus, and Impression Twin Models, effective January 2018. It details the operation, programming, and maintenance of these water treatment systems.

General Operation

The device features a control panel with buttons: CLOCK, REGEN, NEXT, +, and -. Pressing NEXT toggles through five main displays:

  • Time of Day: Shows current time (e.g., 8:20 PM MON). This is the default screen after a reset.
  • Flow Rate: Displays the current water flow rate in GPM (e.g., 8.0 GPM). This indicates the amount of water flowing through and being treated by the unit. The "GPM" and flow rate flash when the turbine is rotating.
  • Capacity Remaining: Shows the unit's remaining capacity in gallons (e.g., 1600 GAL). This screen is not displayed if the unit's capacity is set to OFF. The unit may run into negative capacities and regenerate two nights in a row if it overruns its capacity by a selected percentage.
  • Days to a Regen: Indicates the number of days remaining until the next regeneration (e.g., 3 days). This screen is not displayed if the unit's day override is set to off. "REGEN TODAY" will alternate with the current screen header if a regeneration is expected tonight.
  • Dealer Name/Phone Number: Displays a scrolling dealer name and phone number (e.g., 555-555-5555 DEALER NA). This screen flashes alternately with any of the other chosen displays if set.

To initiate a regeneration to occur tonight, press REGEN from any general operation screen.

Button Sequences

  • Unlock Valve Settings: To change manufacturer's settings, press –, NEXT, +, CLOCK in sequence. To lock settings, repeat the same sequence.
  • Clear Error on Screen: Press and hold NEXT and REGEN for three seconds.
  • Clear Service Alarm: If a service alarm is triggered, press and hold + and – simultaneously for three seconds to reset both gallon and year alarms.

Set Time Screens

Accessed by pressing CLOCK from the general display.

  • Set Hour: Adjusts the hour (e.g., 2:00 AM) using + or – buttons. AM/PM toggles after 12 AM.
  • Set Minutes: Adjusts the minutes (e.g., 2:35 AM) using + or – buttons.
  • Set Current Day: Adjusts the day of the week (e.g., WED) using + or – buttons. The default setting is WED.

Typical Regen Screens

These screens are only visible when the unit is in regeneration.

  • Backwash Remaining: Displays time remaining in the current regeneration cycle (e.g., 2 3:30). The "2" flashes for a second backwash if two backwashes are programmed.
  • Generator On: Displays time remaining in the current cycle (e.g., 53:45 MIN). If an ozone generator is connected and set to ON, its duration is displayed.

Softener Installer/User Screens

Accessed by pressing and holding NEXT and + simultaneously for three seconds. The system returns to the general display after five minutes of inactivity.

  1. Water Hardness: Sets water hardness from 1-150 grains (default 20 GR). This screen is not displayed if the unit is in "FILTERING" mode.
    • Access Dealer Name/Phone Number: From the Water Hardness display, press CLOCK and + simultaneously.
      • Scrolling Contact Phone Number: Sets phone number using + or – buttons. NEXT advances the cursor.
      • Scrolling Contact Name: Sets contact name using + or – buttons. NEXT advances the cursor. (Max 55 characters).
    • To Turn Off Dealer Name/Number Screen: Clear the phone number and dealer name by toggling to "blank" characters using + or – buttons and pressing NEXT.
  2. Days Between Regen: Sets days between regeneration from 1-28 days, or OFF (default 6).
  3. Regen Time Hour: Sets the hour for regeneration (default 2:00 AM). If IMMEDIATE REGEN is set, regeneration occurs immediately once total capacity is exhausted.
  4. Regen Time Minutes: Sets the minutes for regeneration (default 2:00 AM).
  5. Light Normally: Sets backlight operation (default ON). OFF turns off the display backlight after 5 minutes of keypad inactivity. (Only appears on units with backlit display).

Filter Installer/User Screens

Accessed by pressing and holding NEXT and + simultaneously for three seconds. Returns to general display after five minutes of inactivity. (Numbers and cycles are examples for AIR FILTER systems).

  1. Filtering: Selects SOFTENING or FILTERING.
  2. Gallons Capacity: Sets gallons of capacity (default 1000 GAL). Setting to OFF means regeneration is not determined by metered water.
  3. DBL Regen: Sets double regen point (default OFF). If capacity is overrun by this percentage, the unit regenerates two nights in a row.
  4. Backwash-Air: Sets first cycle position (CYCLE 1).
  5. Backwash-Air Time: Sets backwash-air position time (default 20 SEC).
  6. Backwash: Sets second cycle position (CYCLE 2).
  7. Backwash Time: Sets backwash time (default 10:00 MIN).
  8. Regenerant Draw Dn: Sets third cycle position (CYCLE 3).
  9. Draw Time: Sets draw time (default 60:00 MIN).
    • To Set Ozone Generator: Press and hold CLOCK and + simultaneously for three seconds. (Only available if an ozone generator is connected).
      • Ozone Generator: Selects ON/OFF (default ON).
      • Generate Ozone: Sets ozone generator operation time (default 30:00 MIN).
      • Generator Alarm: Selects ON/OFF (default OFF). ON displays "SERVICE OZONE" on user screen if failure is detected.
  10. End: Sets end cycle (CYCLE 4). Up to fourteen cycle positions can be programmed. END triggers the end of regeneration and return to service.

Service/OEM SOFTENING Screens

Accessed by pressing and holding NEXT and – simultaneously for three seconds. Returns to general display after five minutes of inactivity.

  1. Softening: Selects SOFTENING or FILTERING.
  2. Grains of Capacity: Sets system's grains of capacity (default 32.0 X1K).
  3. Gallon Capacity: Sets gallon capacity (default AUTO). AUTO calculates capacity automatically. OFF regenerates by days override only.
  4. DBL Regen: Sets double regen point (default >10%). If capacity is overrun, the unit regenerates two nights in a row.
  5. Fill: Sets first cycle position (CYCLE 1).
  6. Fill: Sets salt pounds per regen (default 15.0 LBS).
  7. Softening: Sets second cycle position (CYCLE 2).
  8. Softening Time: Sets softening time (default 240:00 MIN). This is the time between brine tank fill and start of backwash. During FILL and SOFTENING, the unit delivers soft water.
  9. Backwash: Sets third cycle position (CYCLE 3).
  10. Backwash Time: Sets backwash time (default 12:00 MIN).
  11. Regenerant Draw Dn: Sets fourth cycle position (CYCLE 4).
  12. Draw Time: Sets draw time (default 90:00 MIN).
  13. Rinse: Sets fifth cycle position (CYCLE 5).
  14. Rinse Time: Sets final rapid rinse time (default 4:00 MIN).
  15. End: Sets end cycle (CYCLE 6).

Configuration Screens

Accessed by pressing and holding NEXT and – simultaneously for three seconds. Once the screen changes, press and hold NEXT and – simultaneously again for three seconds.

  1. Valve Type: Selects meter size (default 1.0 IN). Options include 1", 1.25", 1.5", 2", or 1.0T (for twin units). Upflow brining is not an option if not 1" or 1.0T.
    • With 1.0T set: Meter calibration fixed, MAV 1 forced to Alternator Mode w/ Immediate Regen and Post Fill Brining, Backwash-Air regeneration step unavailable.
  2. Delayed Regen: Sets regen time control (default DELAYED).
    • DELAYED: Regen at specified time.
    • DELAY + IMMEDIATE: Regen after 10 minutes of no water usage.
    • IMMEDIATE: Immediate regen upon zero gallons remaining capacity.
    • Pre-Service Rinse (1.0T Mode only): Sets pre-service rinse time from 0-20 minutes (default OFF).
  3. MAV Drive 1: Sets first MAV drive control (default OFF).
    • ALT A and ALT B: Used in twin configurations.
    • SYSTEM CONTROLLER: Configures board for Clack System Controller.
    • SEPARATE SOURCE: Changes state at start and end of regen cycle.
    • NO HARD BYPASS: Configures MAV as no hard water bypass.
    • TIME: Changes state at a set time referenced to start of regen.
    • WARNING: Leaving valve in ALT A, ALT B, or ENABLED without proper hardware results in errors.
  4. Auxiliary Input: Sets auxiliary input (default OFF).
    • IMMED: Unit regens immediately.
    • DELAY: Unit regens after a 2-minute signal from external contact.
    • HOLD: Unit does not regen while external contacts are closed.
    • ALARM: Control valve's internal alarm sounds upon external contact closure.
    • WARNING: External contact is needed for proper operation of these settings.
  5. Relay 1 Trigger: Sets first relay trigger (default OFF). Press + to select triggering event.
    • Time: Relay energized for a specified period during regen.
      • Setpoint: Delay time period after regen starts (default 15 MIN). 0 indicates immediate start.
      • Duration: Duration of time relay remains energized (default 90:00 MIN).
    • Gallons: Relay energized after a specified number of gallons expended in service position.
      • Setpoint: Gallons expended before relay energizes (default 25 GAL).
      • Duration: Duration of time relay remains energized (default 0:30 MIN).
    • Regen Gallons: Relay energized after a specified number of gallons expended during service and regen.
      • Setpoint: Gallons expended before relay energizes (default 25).
      • Duration: Duration of time relay remains energized (default 0:30 MIN).
    • Error: Relay energized when unit is in an error mode.
    • Flow: Relay closes whenever flow is detected.
    • Pulse: Relay generates a dry-contact signal output.
      • Setpoint: Meter pulses per gallon (PPG) (default 1.00 PPG). Adjustable from 0.10 to 10.00 in 1 PPG increments.

First Level History Screens

Accessed by pressing and holding + and - simultaneously for three seconds. Returns to general display after five minutes of inactivity.

  1. Days Since Regen: Displays number of days since last regeneration (e.g., 5).
  2. Volume Since Regen: Displays number of gallons since last regeneration (e.g., 980 GAL).
  3. Reserve For: Displays calculated reserve capacity (e.g., 320 GAL for MON). Use + or – to scroll through each day. Reserve capacity takes 21 days to generate.
  4. Usage: Displays gallon usage history (e.g., DAY 15 230 GAL for WED R). Use + or – to scroll through past 90 days.
    • 1.0T Mode: T1 and T2 usage for this day combined.
    • R: Regen occurred that day.
    • S: Step through manual regeneration.
    • M: Manual regeneration.
    • E: Valve error occurred.
    • Tank Transfer History (1.0T Mode only): Displays last 10 tank transfers.
      • 1: Most recent transfer.
      • A: Service flow from tank.
      • B: Service flow to tank.
      • 3: Days ago of transfer (max 99 days).
      • 0.00: Gallons used at time of transfer.
  5. Max Flow History: Displays peak flow rate history for the last 7 days (e.g., MON 12 GPM).
  6. Total Gallons: Displays total gallons used by Meter 1 input since last reset (e.g., 0 X1K). Press and hold + and – for three seconds to reset to 0.
  7. Total Days: Displays total days unit has been in service (e.g., 970).
  8. Total Regens: Displays total regenerations since startup (e.g., 190).
    • Ozone Current History (when Ozone Generator is on): Reviews ozone generator performance for the past 50 regenerations.
      • MA: Generator current draw in mA (e.g., 260).
      • VDC: Generator voltage in VDC (e.g., 12.0).
    • MAV Drive Time History (units with MAV): Displays drive time history for an active MAV 1 output.
      • First: Average of first three drive times.
      • Last: Last drive time measured.
      • Ave: Current average drive time.
      • TTT: Relative MAV drive time (First/Last/Ave).
      • CCC: Total number of cycles in/out.
      • VVV: Relative MAV drive voltage (First/Last/Ave).

Second Level History Screens

Accessed by pressing + and - simultaneously for three seconds. Once screen changes, press + and - simultaneously again for three seconds. Non-resettable history.

  1. Software Version: Displays software version (e.g., XXXXX).
  2. Total Gallons: Displays total gallons used by Meter 1 since startup (e.g., 0 X1K).
  3. Total Days: Displays total days unit has been in service (e.g., 970).
  4. Total Regens: Displays total regenerations since startup (e.g., 190).
  5. Error Log: Displays last ten valve errors that occurred (e.g., 1 101). Scroll with + or – buttons.

Error Codes and Descriptions

The manual provides a comprehensive list of error codes and their descriptions, ranging from valve movement issues (101-117) to memory errors (402-410).

  • 101 UNABLE TO START: Valve not sensing movement.
  • 102 MOTOR STALLED: Valve unable to find next cycle position.
  • 103 MOTOR RAN TOO LONG: Valve unable to find next cycle position.
  • 104 VALVE HOMING: Valve unable to find Home position.
  • 106 MAV 1 RAN TOO LONG: MAV 1 motor ran too long.
  • 107 MAV 1 STALLED: MAV 1 motor ran too short.
  • 109 INVALID MOTOR STATE: Control cannot operate due to invalid motor state.
  • 116 MAV 2 RAN TOO LONG: MAV 2 motor ran too long.
  • 117 MAV 2 STALLED: MAV 2 motor ran too short.
  • 201 INVALID REGEN STEP: Control cannot operate due to invalid regeneration cycle step.
  • 204 LEAK DETECTED: Check sum error for operational data and status section of EEPROM memory.
  • 402 POWER DOWN MEMORY: Check sum error for operational data and status section of EEPROM memory.
  • 403 PROGRAM MEMORY: Check sum error for programming section of EEPROM memory.
  • 404 DIAGNOSTIC MEMORY: Check sum error for diagnostic section of EEPROM memory.
  • 405 HISTORY MEMORY: Check sum error for history section of EEPROM memory.
  • 406 CONTACT MEMORY: Check sum error for contact screen section of EEPROM memory.
  • 407 STATUS RAM MEMORY FAILURE: Control cannot operate due to corrupted data in Operational Data and Status Section of RAM memory.
  • 408 DIAGNOSTIC RAM MEMORY FAILURE: Control cannot operate due to corrupted data in Diagnostic Data and Status Section of RAM memory.
  • 410 CONFIG DOWNLOAD: Configuration file downloaded was not originally uploaded from another control with identical software revision.

REMINDER: Press and hold NEXT and REGEN for three seconds to perform a soft reset and clear an error on screen.

Water Right Impression Specifications

General IconGeneral
BrandWater Right
ModelImpression
CategoryWater Dispenser
LanguageEnglish

Related product manuals