Shows the current time and day.
Displays the current water flow rate in GPM.
Shows the unit's remaining water capacity in gallons.
Indicates the number of days until the next regeneration.
Alternates with system displays, showing dealer name and phone.
Adjusts the hour and minute for the unit's clock.
Sets the current day of the week for the unit.
Displays the time left in the current regeneration cycle.
Shows time remaining for ozone generator operation, if connected.
Configures the water hardness level in grains per gallon.
Sets the interval in days between automatic regenerations.
Defines the specific hour and minute for regeneration cycles.
Controls the display backlight, with options for ON or OFF.
Allows setting and viewing of dealer contact information.
Sets the interval in days between automatic regenerations.
Defines the specific hour and minute for regeneration cycles.
Controls the display backlight, with options for ON or OFF.
Allows setting and viewing of dealer contact information.
Selects between softening and filtering modes for the unit.
Sets the system's capacity in grains of hardness.
Configures how the unit calculates remaining water capacity.
Sets the percentage of capacity overrun triggering consecutive regenerations.
Defines the sequence and type for the first, second, and third cycles.
Sets the duration for the softening phase of regeneration.
Sets the duration for the backwash phase of regeneration.
Configures fourth, fifth, and end cycle positions for regeneration.
Sets the draw time for the regeneration cycle.
Selects between softening and filtering modes for the unit.
Sets the capacity in gallons for filtering operations.
Sets the percentage of capacity overrun triggering consecutive regenerations.
Configures backwash-air time and second/third cycle positions.
Sets the duration for the backwash phase of regeneration.
Sets the draw time for the regeneration cycle.
Sets ozone generator options, operation time, and alarm settings.
Configures the final cycle position to end regeneration.
Selects the valve type and meter size for unit configuration.
Configures how the unit controls regeneration timing.
Sets the duration for the pre-service rinse cycle.
Configures MAV drive settings and auxiliary input functions.
Configures Relay 1 trigger based on time with setpoint and duration.
Configures Relay 1 trigger based on gallons used with setpoint and duration.
Configures Relay 1 trigger based on regeneration gallons with setpoint and duration.
Configures Relay 1 to trigger when the unit is in an error mode.
Configures Relay 1 to trigger when flow is detected.
Configures Relay 1 for pulse trigger and sets meter pulses per gallon.
Displays the number of days elapsed since the last regeneration.
Shows the total gallons consumed since the last regeneration.
Displays the calculated reserve water capacity.
Provides historical data on daily water usage and regeneration events.
Shows recent tank transfer events and gallons used.
Displays the peak flow rate recorded over the last seven days.
Shows total gallons used by Meter 1 since the last reset.
Displays the total number of days the unit has been operational.
Shows the cumulative number of regenerations performed.
Reviews ozone generator performance over the past 50 regenerations.
Displays drive time history for MAV 1 output.
Displays the current software version of the unit.
Shows total gallons used by Meter 1 since the last reset.
Displays the total number of days the unit has been operational.
Shows the cumulative number of regenerations performed.
Lists the last ten valve errors that occurred on the unit.
Lists common error codes and their descriptions for troubleshooting.