2
Button appearance and position may be different than actual valve
Cycle times, sequences, and settings in this guide are only examples of how your system may be programmed.
Actual settings are determined by the manufacturer. Please contact them if more information is needed.
Important button sequences to note:
1. UNLOCK VALVE SETTINGS: Push buttons in the following order: , NEXT, +, CLOCK. This will allow user to change
manufacturer’s settings. When finished, lock settings by pushing the same sequence.
2. CLEAR ERROR ON SCREEN: Push and hold NEXT and REGEN for three seconds.
3. CLEAR SERVICE ALARM: If service alarm is triggered, push and hold + and simultaneously for three seconds to reset to
original set points. This will reset both gallon and year alarms.
General Operation Screens
Set Time Screens Typical Regen Screens
Pressing NEXT will toggle between one of five displays. Press REGEN to set a regeneration to occur tonight.
Accessed by pressing CLOCK. Only visible when unit is in regeneration.
DAYS TO A REGEN
GPM
3
8
CAPACITY REMAINING
GPM GAL
1600
8
FLOW RATE
GPM
8.0
TIME OF DAY MON
GPM
2:408
PM
“GPM” and flow rate
flash while turbine is
rotating
Return to general display
Return to general display
“REGEN TODAY”
will alternate with the
current screen header
if a regen is expected
tonight
Displays current time.
Unit defaults to this screen
after a reset.
Displays a unit’s remaining capacity.
This screen will not display if the unit’s gallons of
capacity is set to OFF. The unit may run into negative
capacities and will regenerate two nights in a row if
it overruns its capacity by the selected percentage.
Displays days remaining until a regen.
This screen will not display if the unit’s day
override is set to off.
Set hours with + or — buttons.
AM/PM toggles after 12 AM.
Displays time remaining in
current regeneration cycle
“2” flashes for a second backwash if
two backwashes are programmed.
Displays time remaining in
current cycle
If an ozone generator is connected and set to ON,
the duration of the ozone generation is displayed.
Set minutes with + or — buttons.
AM/PM toggles after 12 AM.
Set current day with + or — buttons.
The default setting is WED.
Displays scrolling dealer name
and phone number.
To change dealer name and phone
number, see page 3 or 4.
Displays current flow rate.
“Current Flow Rate” is the amount of
water currently flowing through, and
being treated by, the unit.
555 5555555
DEALER NA
Any one of these chosen
displays will flash alternately
with dealer name screen if set.
CURRENT DAY
SET
WED
TIME MINUTES
SET
TIME HOUR
SET
2:00
2:35
AM
AM
MIN
BACKWASH REMAINING
2
3:30
GENERATOR ON
53:45