EasyManua.ls Logo

Water Right IMPC-1035 - User Manual

Water Right IMPC-1035
32 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Impression Series
®
Impression RC Series
Metered Water Softeners
For Models:
• IM-844 • IMP-844
• IM-948 • IMP-948
• IM-1044 • IMP-1044
• IM-1054 • IMP-1054
• IM-1248 • IMP-1248
• IM-1354 • IMP-1354
• IMC-835 • IMPC-835
• IMC-1035 • IMPC-1035
• IMRC-1054 • IMPRC-1054
• IMRC-1354 • IMPRC-1354

Other manuals for Water Right IMPC-1035

Questions and Answers

  • D
    danielle52Sep 14, 2025
    Why does my Water Right IMPC-1035 control valve regenerate at the wrong time of day?
    • G
      gonzalezkellySep 14, 2025
      If your Water Right Water Dispenser control valve regenerates at the wrong time, it could be due to the following reasons: * A power outage may have occurred: Reset the time of day. If your PC board has a battery backup, it may be depleted. * The time of day may not be set correctly: Reset it to the correct time. * The regeneration time may be set incorrectly: Reset the regeneration time. * The control valve may be set at immediate regeneration: Check the programming setting and reset to DELAYED for a delayed regeneration time.
  • R
    Rebekah RobinsonAug 25, 2025
    What to do if Water Right Water Dispenser control valve only regenerates when buttons are held?
    • K
      Kelly SimpsonAug 26, 2025
      If your Water Right Water Dispenser's control valve doesn't regenerate automatically unless you press and hold the correct buttons, several factors could be responsible. First, check if the bypass valve is in the bypass position and turn the bypass handles to place it in the service position. Ensure the meter is correctly connected to the meter connection on the PC board. A restricted or stalled meter turbine can also cause this issue; remove the meter and check for rotation or foreign material. Incorrect programming could be the problem, so review the settings for errors. Also, verify that the meter wire is securely installed into the three-pin connector labeled METER. If these steps don't resolve the issue, the meter or the PC board might be defective and need replacement.
  • C
    Carlos BarnesAug 26, 2025
    Why does my Water Right IMPC-1035 Water Dispenser regenerate at the wrong time?
    • C
      Clinton PetersAug 26, 2025
      If the control valve on your Water Right Water Dispenser regenerates at the wrong time of day, it could be due to several reasons. A power outage might have occurred; reset the time of day. If your PC board has a battery backup, it may be depleted. Also, the time of day might not be set correctly, so reset it to the correct time. The regeneration time itself might be set incorrectly, so reset that as well. Finally, the control valve might be set at immediate regeneration; check the programming and reset it to DELAYED for a delayed regeneration time.
  • L
    Lisa WilkinsDec 1, 2025
    How do I fix error E1 on my Water Right IMPC-1035?
    • D
      Daniel SantiagoDec 1, 2025
      If your Water Right Water Dispenser displays error codes E1, Err – 1001, or Err – 101, it indicates that the control is unable to sense motor movement. Ensure the motor is fully inserted to engage the pinion, and check for broken or disconnected motor wires. Make sure the two-pin connector on the motor is connected to the corresponding connection on the PC board labeled MOTOR. Disconnect power, then press the NEXT and REGEN buttons for 3 seconds to resynchronize the software with the piston position, or disconnect the power supply from the PC board for 5 seconds and then reconnect it. Also, ensure the PC board is properly snapped into the drive bracket. If there are missing drive gears, replace them. If the motor doesn't drive or run, replace it. Check if the viewing eye or encoder is bloc...
  • D
    Danielle HowellSep 14, 2025
    What does it mean when the time of day flashes on and off on my Water Right IMPC-1035?
    • T
      Travis FloydSep 15, 2025
      If the time of day is flashing on and off on your Water Right Water Dispenser, it indicates a power outage. You should reset the time of day. If the PC board has a battery back up, the battery may be depleted.
  • G
    George CaseySep 23, 2025
    What does error E4 mean on my Water Right IMPC-1035 Water Dispenser?
    • C
      cgarciaSep 23, 2025
      Error E4, Err – 1004, or Err – 104 on your Water Right Water Dispenser indicates that the control valve motor ran too long and timed out trying to reach the home position. This can be caused by: * A drive bracket that is not snapped in properly, preventing the reduction gears and drive gear from interfacing. Snap the drive bracket in properly, then press the NEXT and REGEN buttons for 3 seconds to resynchronize the software with the piston position, or disconnect the power supply from the PC board for 5 seconds and then reconnect it. * A piston not connected to the drive cap. Connect or replace the piston/drive cap if damaged.
  • H
    Holly KingSep 4, 2025
    How to troubleshoot no display on Water Right Water Filtration Systems?
    • M
      Mark FreySep 5, 2025
      If your Water Right Water Filtration System displays no image on the PC board, it could be due to several reasons: * There's no power at the electrical outlet. Solution: Repair the outlet or use a working one. * The control valve power adapter isn't plugged in. Solution: Plug the power adapter into the outlet, or connect the power cord to the PC board connection. * There's an improper power supply. Solution: Verify the correct voltage is being supplied to the PC board. * The power adapter is defective. Solution: Replace the power adapter. * The PC board itself is defective. Solution: Replace the PC board.
  • L
    Lauren JohnsonSep 8, 2025
    Why Water Right Water Filtration Systems control valve fails to draw in regenerant?
    • B
      burnsbrettSep 8, 2025
      If your Water Right Water Filtration System's control valve fails to draw in regenerant, it could be due to: * A plugged injector. Solution: Remove the injector and clean or replace it. * A faulty regenerant piston. Solution: Replace the regenerant piston. * A regenerant line connection leak. Solution: Inspect the regenerant line for an air leak. * A drain line restriction or debris causing excess back pressure. Solution: Inspect the drain line and clean it to correct the restriction. * A drain line that's too long or too high. Solution: Shorten the length and/or height. * Low water pressure. Solution: Check the incoming water pressure – it must remain at a minimum of 25 psi.
  • J
    Jeremy SullivanSep 23, 2025
    Why is water running to drain in my Water Right Water Dispenser?
    • G
      gmercadoSep 23, 2025
      If water is running to the drain in your Water Right Water Dispenser, it could be due to: * A power outage during regeneration: Upon power restoration, the control will finish the remaining regeneration time. Reset the time of day. If the PC board has a battery back up, it may be depleted. * Damaged seal/stack assembly: Replace the seal/stack assembly. * Piston assembly failure: Replace the piston assembly. * Drive cap assembly not tightened properly: Re-tighten the drive cap assembly.
  • L
    laura46Aug 30, 2025
    Why is the time of day flashing on my Water Right Water Dispenser?
    • R
      Robert BrooksAug 30, 2025
      If the time of day is flashing on and off on your Water Right Water Dispenser, it's likely due to a power outage. Reset the time of day. If the PC board has a battery backup, it may be depleted.

Summary

Pre-Installation Instructions for Dealers

Bypass Valve Operation

Installation

General Installation & Service Warnings

Crucial safety and installation guidelines for proper setup.

Site Requirements

Necessary environmental and physical conditions for unit placement.

Programming Procedures

Setting the Time of Day

Procedure to set the current time on the control panel.

Configuring System Settings

Steps to adjust hardness, regeneration, and time parameters.

Startup Instructions

Operating Displays and Maintenance

General Operation Displays

Overview of the four main system status displays.

Regeneration Modes

Explains normal and manual regeneration cycles.

Power Loss and Battery Maintenance

Procedures for power outages and battery replacement.

Error Messages and Troubleshooting

Interpretation of error codes and basic troubleshooting steps.

Brine Tank Care

Guidelines for maintaining the brine tank and salt.

RC Unit Features

Information about Resin Carbon units for water treatment.

Troubleshooting Guide

Replacement Parts

Front Cover and Drive Assembly

Components for the control panel and drive mechanism.

Piston Assembly Components

Parts related to the internal piston mechanism.

Control Valve Assemblies

Various valve components including bypass, brine elbow, and check valve.

Injector and Meter Assemblies

Parts for injector systems and water meters.

Drain Line Components

Parts associated with the system's drain line.

Brine Tank and Cabinet Parts

Components for the brine tank and outer cabinet.

Installation Fitting Assemblies

PVC and Solvent Fittings

Various PVC and solvent-weld fittings for plumbing connections.

Brass Sweat Fittings

Fittings for connecting via brass sweat joints.

Plastic and Shark Bite Fittings

Fittings for plastic pipe and Shark Bite connections.

John Guest Elbow Fittings

Push-to-connect John Guest elbow fittings.

Specifications

IM;IMC Series Specifications

Technical data for Impression and Impression C series models.

IMRC Series Specifications

Technical data for Impression RC series models.

Cycle Times and Usage Data

Details on regeneration cycle durations and water usage.

Water Softener Limited Warranty

Quick Reference Guide

General Operation and Displays

Overview of system displays and basic operation.

Setting System Time and Date

Instructions for setting the unit's clock.

Bypass Valve and Regeneration Adjustments

Guides for bypass operation and adjusting regeneration settings.

Manual Regeneration Procedure

Steps to initiate a manual regeneration cycle.

Water Right IMPC-1035 Specifications

General IconGeneral
BrandWater Right
ModelIMPC-1035
CategoryWater Dispenser
LanguageEnglish

Related product manuals