Water Right Impression - Relay 1 Regen Trigger Settings; Relay 1 Error Trigger; Relay 1 Flow Trigger; Relay 1 Pulse Trigger and Setpoint

Water Right Impression
16 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
11
cont’d
0:30
MIN
RELAY 1 TRIGGER
SET
REGEN
RELAY 1 TRIGGER
SET
ERROR
RELAY 1 SETPOINT
SET
25
GAL
RELAY 1 DURATION
SET
RELAY 1 SETPOINT
SET
1.00
PPG
RELAY 1 TRIGGER
SET
PULSE
RELAY 1 TRIGGER
SET
FLOW
Configuration Screens
Accessed by pressing and holding NEXT and simultaneously for three seconds.
Once screen changes, press and hold NEXT and simultaneously again for three seconds.
continued from previous page
Set relay trigger with + or — buttons.
REGEN GALLONS indicates that relay will be energized after a specified number of
gallons are expended during service and regen. To set by this, press NEXT.
Set relay trigger with + or — buttons.
ERROR indicates that relay will be energized while unit is in an error mode. To set by
this, press NEXT.
Set relay trigger with + or — buttons.
FLOW indicates that relay will close whenever flow is detected by the control. To set
by this, press NEXT.
Set relay trigger with + or — buttons.
PULSE indicates that relay will generate a dry-contact signal output. To set by this,
press NEXT.
Set relay setpoint with + or — buttons.
This is the gallons that will be expended before relay will
initially energize.
Set relay setpoint with + or — buttons.
Set meter pulses per gallon (PPG). Adjustable
from 0.10, 0.25, 0.50, 0.75, and 1.00 – 10.00
in 1 PPG increments.
Set relay duration with + or — buttons.
This is the duration of time, after relay setpoint, that relay
will remain energized. Adjustable from 1 sec to 500 min.
Return to
General Display
Return to
General Display
Return to
General Display
Return to general display