Water Right Impression - Service;OEM FILTERING Screens; Filtering Type Selection; Gallons Capacity for Filtering; Double Regeneration Point (Filtering)

Water Right Impression
16 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7
DBL REGEN
SET
>10%
CYCLE 1
20
SEC
BACKWASH-AIR
SET
BACKWASH-AIR TIME
SET
GAL
GALLONS CAPACITY
SET
1000
FILTERING
SET
TYPE
CYCLE 2
BACKWASH
SET
CYCLE 3
REGENERANT DRAW DN
SET
10:00
MIN
BACKWASH TIME
SET
1
2
3
4
5
6
7
8
Service/OEM FILTERING Screens
Accessed by pressing and holding NEXT and simultaneously for three seconds.
Returns to general display after five minutes of inactivity.
NOTE: Numbers and cycles used as examples on this page are typical of AIR FILTER systems.
Select SOFTENING or FILTERING with + or — buttons.
If you have selected SOFTENING, please refer to
“Service/OEM SOFTENING screens”, page 5-6.
Set gallons of capacity with + or — buttons.
To turn off, set below 0. OFF does not use metered water to
determine a regen and will not be an option of days override
is not set. Default setting is 1000 gallons.
Set double regen point with + or — buttons.
If unit’s capacity is overrun by this percentage, the unit will
regen two nights in a row. Default setting is OFF.
Set first cycle position with + or — buttons.
Set backwash-air position time with + or — buttons.
Default setting is 20 seconds.
Set backwash time with + or — buttons.
Default setting is 10:00 minutes.
Set second cycle position with + or — buttons.
Set third cycle position with + or — buttons.
continue to next page