13
cont’d
TOTAL REGENS
190
TOTAL DAYS
970
MON
GPM
12
MAX FLOW HISTORY
TOTAL GALLONS
X1K
0
VVVCYC
TTT
MAV 1 - FIRST
CCC
mA VDC
REGEN 1
OZONE
260 12.0
5
6
7
8
First Level History Screens
Accessed by pressing and holding + and — simultaneously for three seconds.
Returns to general display after five minutes of inactivity.
continued from previous page
Displays peak flow rate history.
Use + or — buttons to scroll through last 7 days to view peak
flow rate for that day.
Displays ozone current history.
Use + or — buttons to review ozone generator performance during the past 50 regenerations.
A regen sequence indicator (A) will alternated being viewed with “mA” if the Alternate Regen
Feature was active for this regen. Regens with multiple regenerate draws will only record the
first one in the sequence. Values displayed are determined immediately after a low output current
is detected, or will be the average values measured during generator period of operation.
AAA = Generator current draw in mA
VV.V = Generator voltage in VDC
Viewed only if SERVICE/OEM is set to OZONE ON.
Displays MAV drive time history for an active MAV 1 output..
Use + or — buttons to select a MAV output. Pushing both + and — buttons
will reset this display.
First = Average of the first three drive times measured for that MAV in that direction.
Last = Last drive time measured for that MAV in that direction.
Ave = Current average drive time calculated for that MAV in that direction.
TTT = Relative MAV drive time measured (First/Last/Ave).
CCC = Total number of cycles in/out for that MAV.
VVV = Relative MAV drive voltage measured (First/Last/Ave).
Displays total days unit has been in service.
Displays total regens since startup.
Displays total gallons used by Meter 1
input since last reset.
Push and hold + and — buttons simultaneously for
three seconds to reset this value back to 0 gallons.
Return to general display
Only appears
when OZONE
GENERATOR
is on.
Only appears on
units equipped
with MAV.