EasyManua.ls Logo

Water Tech REIONATOR Classic Series - User Manual

Water Tech REIONATOR Classic Series
8 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Care and Use Guide
REIONATOR
Classic Series
with Triton Electronic Control Valve
WQA Gold Seal certi ed to NSF/ANSI Standards 42 and
44 for meeting or exceeding industry standards of
aesthetic chlorine reduction and softening ef ciency.
Water Tech Industries Residential REIONATOR
LIMITED LIFETIME WARRANTY
Applicable to REIONATOR
Classic Models:
RC32-TM, RC40-TM, RC48-TM, RC64-TM, RC80-TM
Water Tech Industries (WTI) hereby warrants said equipment, only to the original purchaser at the original
installation location.
THIS WARRANTY PERIOD BEGINS at the time of initial installation and use. The warranty becomes valid upon
registration of the equipment.
LIMITED LIFETIME WARRANTY ON CONDITIONER AND BRINE TANK – Water Tech Industries will replace or re-
pair (at WTI option) any conditioner tank that becomes unusable because of leakage, corrosion or rupture.
All internal mechanical components are warranted for a period of ve years from date of installation.
LIMITED LIFETIME WARRANTY ON RESIN – The REIONATOR has been equipped with the highest quality NSF
certi ed water treatment media. If, upon factory inspection, the resin is found to be defective, Water Tech
Industries will furnish replacement resin. The resin warranty does not cover resins subjected to water con-
taining greater than 3.0-ppm of free chlorine or chloramines or containing greater than 1.0-ppm total Iron
and/or Manganese. Resin which has been fouled by iron, manganese, organics (or other contaminants not
designed for treatment by the REIONATOR) is not covered.
LIMITED LIFETIME WARRANTY ON CONTROL VALVE - The REIONATOR has been equipped with the highest
quality water conditioning control valves available. If, upon factory inspection, the control valve body or PC
board is found to be defective, WaterTech Industries will furnish repair or replacement (at WTI option) of
the control valve body and/or the PC board. All internal mechanical components are warranted for a period
of ve years from the date of installation
EXCLUSIONS AND LIMITATION OF LIABILITY – Water Tech Industries' liability for special, incidental, or
consequential damages is expressly disclaimed. In no event shall Water Tech Industries' liability exceed
the obligation of repairing or replacing any part that becomes defective under valid warranty coverage as
described above. Cosmetic damage that does not affect the process functionality of the equipment is not
covered. Water Tech Industries makes every effort to ensure that all illustrations and speci cations are
correct. However, these do not imply a warranty that the product is merchantable or t for a particular
purpose, or that the product may not vary from the illustrations and speci cations. The warranty contained
herein is in lieu of all other warranties, expressed or inferred, including any implied warranty of tness
for a particular purpose. Labor and transportation costs incidental to the delivery or replacement of parts
other than WTI factory repairs are not covered under this warranty. In the event of a warranty replacement
or repair, WTI will cover the cost of shipping the covered components. This warranty expressly excludes any
system which has been damaged by accident, re, ood, Act of God, abuse, neglect, freezing, excessive
temperature (below 40° F or above 110° F.), inappropriate pressure (below 20psi or above 100psi), misuse,
alteration, product identi cation tampering, misapplication, installation or operation not consistent with
WTI instructions and installation outside of applicable plumbing codes and local regulations. Ful llment
of the warranty coverage by WTI is contingent on proper execution of the procedures set forth in the WTI
Warranty RMA policy. No person or representative is authorized to assume for Water Tech Industries any
liability on its behalf, or in its name, except to refer the purchaser to this warranty. This warranty gives you
speci c legal rights, you may also have other rights which vary from state to state.
WHAT MUST YOU DO TO OBTAIN WARRANTY SERVICE - The warranty registration card must be lled out
completely and returned to Water Tech Industries within thirty days of installation to validate the REION-
ATOR Limited Lifetime Warranty. Units that have not been registered will be covered under the Standard
Product Warranty rather than the Limited Lifetime Warranty. Repair work should be performed by an autho-
rized Water Tech Dealer. In the event that authorized dealer service is not available, defective components
may be returned directly to Water Tech Industries for warranty service. The registered owner must return
the defective component, freight prepaid, with proof-of-purchase, within the applicable warranty period.
P: 888-254-8412 • F: 503-261-9118 • 13110-3 NE Airport Way, Portland, OR 97230 • watertech.com
R 10/12/07
Question and Answer IconNeed help?

Do you have a question about the Water Tech REIONATOR Classic Series and is the answer not in the manual?

Summary

Water Tech REIONATOR Limited Lifetime Warranty

Warranty on Conditioner and Brine Tank

Details the warranty for the conditioner tank and internal mechanical components.

Warranty on Resin

Covers defects in the REIONATOR's resin, excluding specific water conditions.

Warranty on Control Valve

Warrants the control valve body and PC board against defects.

Exclusions and Limitations of Liability

Disclaims liability for consequential damages and outlines warranty exclusions.

Obtaining Warranty Service

Explains the process for registering and obtaining warranty service.

Specifications

System Overview

Describes the REIONATOR as a demand initiated regeneration softener.

Performance Standards

Details conformance to NSF/ANSI standards for chlorine reduction and softening.

Specifications

Salt Efficiency and Capacity Data

Provides data on softening efficiency and capacity based on salt settings.

Flow Rate and Bed Depth Data

Lists service flow rates, regeneration flow, and bed depths for models.

Operating Parameters

Details minimum/maximum working pressure, temperature, and voltage.

Maintenance

Routine Maintenance Tips

Guidance on checking salt levels and using premium regenerant salt.

Troubleshooting Service Issues

Covers display issues, power outages, and changes in water quality.

Dos and Do Nots

Recommended Practices

Guidelines on installation, usage, inspection, and contacting dealers.

Actions to Avoid

Prohibits actions like hanging items, reprogramming, or using unsafe water.

Bypass Valve Illustrations

Valve Positions Explained

Illustrates and explains Normal Operation, Bypass, Diagnostic, and Shut Off positions.

Bypass Valve Operation

Valve Design and Features

Describes the bypass valve's non-metallic design, seals, and plug valve operation.

Understanding Valve Positions

Explains the function of Normal Operation, Bypass, Diagnostic, and Shut Off positions.

Plumbing Connection

Installation Diagram

Illustrates the typical plumbing connections for the REIONATOR system.

Set Time of Day; Power Loss

Time Setting Procedure

Instructions for setting the time after power outages or daylight saving changes.

Understanding Error Messages

Provides guidance on interpreting and responding to error codes.

Displays & Programming Instructions

General Operation Display Modes

Explains the main screen displays for current time, days, or gallons remaining.

Regeneration Mode Indicators

Describes how the system indicates an automatic regeneration is scheduled.

Manual Regeneration Procedures

Details how to initiate manual regeneration for immediate or scheduled cycles.

Drain Line Connection

Connection Caution

Warning about connecting the drain line to prevent back siphoning.

Starting Up the System

Flushing, Conditioning, and Sanitizing

Step-by-step guide to properly flush, condition, and sanitize the system after installation.

Displays & Programming Instructions

General Operation Display Details

Elaborates on display options for days remaining vs. gallons remaining.

Regeneration Mode Signal Details

Explains how the system signals an automatic regeneration is scheduled.

Manual Regeneration Initiation Details

Instructions for starting regeneration immediately or at a scheduled time.

Water Tech REIONATOR Classic Series Specifications