www.waterco.com
WARNING
!
HYDROCHLOR ST
mineral chlorinator
Owners Manual
This equipment must be installed and serviced by a qualified technician.
Improper installation can create electrical hazards which could result in
property damage, serious injury or death. Improper installation will void the
warranty.

Questions and Answers

Summary

Whats in the Box?

Hydrochlor ST Control Unit

Components included in the packaging of the Hydrochlor ST.

Manual Warranty Booklet

Documentation detailing the warranty terms and conditions for the product.

FEATURES

Chlorine Generation

Explanation of the electrolysis process for producing chlorine.

Electrolytic Salt Cell

Description of the salt cell component and its construction.

Self-Cleaning

Details on the automatic polarity reversal for cleaning the salt cell electrodes.

INSTALLATION

PLUMBING DIAGRAM

Visual representation of the system's pipework connections.

Installing the Control Unit

Guidance on selecting a location and connecting the control unit.

Installing; Connecting Electrolytic Cell

Instructions for plumbing the salt cell and connecting its cables.

OPERATION

Setting the time

Procedure for setting the current time on the unit's timer.

Manual Override Switch

Explanation of the ON, AUTO, and OFF positions for the timer override.

CHLORINE PRODUCTION LEVELS

How to adjust chlorine output and use Pump Only mode.

ALARMS

Low Chlorine Production Level LED blinking

Indicates low salt level, requiring salt addition.

High Chlorine Production Level LED blinking

Signifies moderately high salt level needing reduction.

Max Chlorine Production Level LED Amber

Alerts to excessively high salt level, stopping production.

No Water Flow

Indicates the flow sensor is not detecting water movement.

WATER CHEMISTRY

Salt Level

Recommended operating ranges for salt levels (TDS).

Water Chemistry

Optimal chemical balance levels for pool water.

SALT CELL CLEANING PROCEDURE

TROUBLESHOOTING

Low chlorine level in pool

Addresses causes like short operating time or incorrect salt.

Unit does not operate

Covers issues like no power or unit being switched off.

Not keeping time

Possible causes include timer setting or power outage.

All LEDs blinking

Indicates an electrical fault requiring professional attention.

No chlorine production

Troubleshooting for incorrect settings or pump-only mode.

Pump not working

Checks for pump connection, water level, and flow sensor.

TECHNICAL SPECIFICATIONS

GENERAL SAFETY RULES

WARRANTY

Waterco HYDROCHLOR ST Specifications

General IconGeneral
TypeSalt Water Chlorinator
UsageResidential Pools
Power Supply220-240V, 50Hz
Cell TypeSelf-cleaning electrolytic cell
Salt Level4000-6000 ppm