www.waterco.com
WARNING
!
HYDROCHLOR ST
mineral chlorinator
Owners Manual
This equipment must be installed and serviced by a qualified technician.
Improper installation can create electrical hazards which could result in
property damage, serious injury or death. Improper installation will void the
warranty.

Questions and Answers

  • J
    Jacob BlackburnAug 5, 2025
    Why is the chlorine level low in my Waterco Water Filtration System?
    • M
      Marilyn LewisAug 5, 2025
      If your Waterco Water Filtration System shows a low chlorine level in the pool, several factors could be at play. First, ensure that the operating time is sufficient; if it's too short, increase it. Next, check the production control setting and increase it if it's set too low. Also, verify the salt level and add the required amount if it's low. Finally, incorrect pool chemistry can also cause this issue, so have your water tested.
  • C
    Cole RubioAug 10, 2025
    What to do if my Waterco Water Filtration System has no chlorine production?
    • J
      Jennifer DouglasAug 11, 2025
      If your Waterco Water Filtration System isn't producing chlorine, make sure the control unit isn't set to 'pump only'. Press the Chlorine Production button to set the desired level. Also, check that the timer isn't in the OFF position; set it to ON or AUTO.
  • L
    Lisa FordAug 17, 2025
    Why my Waterco Water Filtration System does not operate?
    • J
      Jordan StevensAug 17, 2025
      If your Waterco Water Filtration System unit isn't operating, first ensure it's receiving electrical power by connecting it and checking the fuse. Also, verify that the Hydrochlor ST switch is turned on.
  • M
    Marcus KellerAug 23, 2025
    How to troubleshoot a Waterco Water Filtration System pump that is not working?
    • D
      destiny76Aug 23, 2025
      If the pump of your Waterco Water Filtration System isn't working, start by ensuring it's properly connected to the pump socket outlet. Also, check the pool water level, the position of the multiport valve, and the connection of the flow sensor pin to ensure there is flow detected.
  • R
    Roger BlakeAug 28, 2025
    What does it mean when all LEDs are blinking on my Waterco Water Filtration System?
    • C
      Charles Garcia DVMAug 28, 2025
      If all the LEDs on your Waterco Water Filtration System are blinking, this indicates an electrical fault. You should return it to the distributor for repair.

Summary

Whats in the Box?

Hydrochlor ST Control Unit

Components included in the packaging of the Hydrochlor ST.

Manual Warranty Booklet

Documentation detailing the warranty terms and conditions for the product.

FEATURES

Chlorine Generation

Explanation of the electrolysis process for producing chlorine.

Electrolytic Salt Cell

Description of the salt cell component and its construction.

Self-Cleaning

Details on the automatic polarity reversal for cleaning the salt cell electrodes.

INSTALLATION

PLUMBING DIAGRAM

Visual representation of the system's pipework connections.

Installing the Control Unit

Guidance on selecting a location and connecting the control unit.

Installing; Connecting Electrolytic Cell

Instructions for plumbing the salt cell and connecting its cables.

OPERATION

Setting the time

Procedure for setting the current time on the unit's timer.

Manual Override Switch

Explanation of the ON, AUTO, and OFF positions for the timer override.

CHLORINE PRODUCTION LEVELS

How to adjust chlorine output and use Pump Only mode.

ALARMS

Low Chlorine Production Level LED blinking

Indicates low salt level, requiring salt addition.

High Chlorine Production Level LED blinking

Signifies moderately high salt level needing reduction.

Max Chlorine Production Level LED Amber

Alerts to excessively high salt level, stopping production.

No Water Flow

Indicates the flow sensor is not detecting water movement.

WATER CHEMISTRY

Salt Level

Recommended operating ranges for salt levels (TDS).

Water Chemistry

Optimal chemical balance levels for pool water.

SALT CELL CLEANING PROCEDURE

TROUBLESHOOTING

Low chlorine level in pool

Addresses causes like short operating time or incorrect salt.

Unit does not operate

Covers issues like no power or unit being switched off.

Not keeping time

Possible causes include timer setting or power outage.

All LEDs blinking

Indicates an electrical fault requiring professional attention.

No chlorine production

Troubleshooting for incorrect settings or pump-only mode.

Pump not working

Checks for pump connection, water level, and flow sensor.

TECHNICAL SPECIFICATIONS

GENERAL SAFETY RULES

WARRANTY

Waterco HYDROCHLOR ST Specifications

General IconGeneral
TypeSalt Water Chlorinator
UsageResidential Pools
Power Supply220-240V, 50Hz
Cell TypeSelf-cleaning electrolytic cell
Salt Level4000-6000 ppm