INSTALLATION INSTRUCTIONS
LOW VOLTAGE SHOWER PUMPS
Models PC25DLV PC50DLV
PC55SLV PC70DLV ANHPC60DLV
CUSTOMER SERVICE HELPLINE:
01883 730339
Performance Shower Products
Question and Answer IconNeed help?

Do you have a question about the Watermill PC25DLV and is the answer not in the manual?

Watermill PC25DLV Specifications

General IconGeneral
BrandWatermill
ModelPC25DLV
CategoryWater Pump
LanguageEnglish

Summary

GENERAL

IMPORTANT INSTRUCTIONS

Installation Safety & Restrictions

Avoid mains pressure, use correct jointing, flexible hoses, and ensure electrical safety.

Pump Head & Positioning Requirements

Minimum 2m supply head from tank to pump; consider positioning for maintenance and water damage mitigation.

Operational & Maintenance Checks

Purge pump, test system, check temperature limits, and inspect hoses/connections regularly.

POSITIONING PUMP

Negative Head Systems Explained

Details requirements for negative head systems, including specific pump types or kits.

Mounting & Noise Reduction

Mount pump horizontally with outlets vertical; use a slab for vibration and noise reduction.

HOT WATER CYLINDER CONNECTIONS

COLD WATER SUPPLY

CONNECTING PUMP

Flexible Hose and Filter Connection

Use supplied flexible hoses; insert filters with wire dome towards pump on inlets.

ELECTRICAL CONNECTIONS

Low Voltage Pump Operation

Use supplied transformer; do not connect pump directly to 240V. Ensure transformer is outside wet areas.

Transformer to Pump Wiring

Connect BROWN to Live (L) and BLUE to Neutral (N) terminals.

Earthing and Bonding

Supplementary earth bonding for copper pipes and flexible connections using BS951 clamps.

BEFORE USING

Initial System Priming and Testing

Fill system, check for leaks, run pump without handset, then with handset, re-check for leaks.

Initial Motor Odour

Initial motor odour from insulating varnish is normal and will diminish.

FAULT FINDING

Troubleshooting Pump Start Issues

Check electricity, valves, thermal cutouts, flow switches, and blocked filters.

Troubleshooting Pump Stop Issues

Check mixer valve, air entrapment, and flow switch for pump not turning off.

Addressing Temperature/Noise Issues

Air in hot water supply causes erratic operation, noise, and unstable temperature.

GUARANTEE OF CORRECT INSTALLATION

Installer's Installation Checklist

Installer must confirm correct installation by ticking important instructions on the guarantee form.

TECHNICAL DATA

Electrical Specifications

Details transformer input/output, power consumption, rating, and motor type for different models.

Mechanical Specifications

Covers inlet head, maximum developed head, working pressure, and approximate flow rate.

Physical Dimensions and Noise Level

Provides length, width, height dimensions and sound pressure level at 1 meter.

Product Guarantee Information

Product Guarantee Terms

Two-year warranty requires registration and proof of purchase; guarantee reverts to manufacture date if un-registered.

Guarantee Registration Card

Form to be completed with product, customer, and purchase details for warranty activation.

GUARANTEE CLAIM PROCEDURE

Initial Support and Information Needed

Phone helpline; have guarantee acknowledgement, proof of purchase, and pump serial number ready.

Site Visit Policy and Charges

Explains conditions for free vs. chargeable site visits and adult presence requirement.

Return Address for Service

Provides the official return address for Watermill Products Limited.

Related product manuals