48/56 Frame Power Defender Executive, EX2, & Viper Pump Instructions
ALL ELECTRICAL INSTALLATIONS SHOULD BE PERFORMED BY QUALIFIED ELECTRICIANS
2-SPEED MODELS: DO NOT wire both speeds to run simultaneously. If supply cord is damaged, replace
only with original replacement equipment available from authorized dealer.
The pump is to be supplied through a residual current device (RCD) with a rated residual operating current not
exceeding 30mA.
Potential risk of fire, electrical shock, or injury to persons if misused.
DO NOT install within an outer enclosure or beneath the skirt of the spa unless so marked.
WARNING: To reduce the risk of injury, do not permit children to use this product unless they are closely
supervised at all times.
CAUTION: This pump is for use with permanently installed pools and may also be used with hot tubs and spas
if so marked. Do not use with storable pools. A permanently installed pool is constructed in or on the ground
or in a building such that it cannot be readily disassembled for storage. A storable pool is constructed so that it
may be readily disassembled for storage and reassembled to its original integrity.
PUMP CONNECTIONS INSTALLATION INSTRUCTIONS
LOCATION: Place pump on level surface. Pump must be installed below water surface. Shut off valves should be
installed on both the inlet and outlet of the pump for future maintenance. Installation area should be clear of any
direct water and have adequate floor drainage. Pump should be protected from excessive moisture.
The inlet and outlet have Waterway male union threads. Use Waterway tailpiece assemblies for best connection.
These unions allow the pump to be removed for service without disturbing the plumbing. HAND TIGHTEN UNIONS
ONLY!
DO NOT use pipe dope. Use only Teflon tape or other sealing compounds approved for use with plastic. Some pipe
dopes not approved for use with plastic will cause stress cracking of plastic parts. New installations often require
a plumbing inspection. This inspection is usually conducted using city water pressure. A pressure regulator should
be used when preforming this test and should not exceed 40 PSI during the pressure test. The filter and pump are
under pressure. Insure that all air is removed during the pressure test. FAILURE TO FOLLOW THESE INSTRUCTIONS
EXPLICITLY CAN RESULT IN PERSONAL INJURY.
MOTOR WIRING
1. Before working on any electrical connections be sure that the power is turned off.
2. All wiring must conform to local, state and/or national codes.
3. All wiring must conform to wiring diagram on the motor nameplate or on the back of the terminal cover.
4. Applied voltage must correspond to the rated voltage as indicated on the marking plate.
5. FOR SAFETY CLASS 1 EQUIPMENT: It is mandatory to connect the pump to the protective conductor
(grounding connector) of the earth-grounded main power supply.
FOR EQUIPOTENTIAL BONDING: It is also possible in addition to use the external terminal on the body to
realize an equipotential bonding with other earthed metallic parts.
6. DO NOT ground to a gas supply line.
7. Ground motor prior to connecting electrical power.
8. For disconnection from the supply, a circuit breaker having a contact separation of at least 3mm in all poles
must be incorporated in the fixed wiring according to the wiring rules. Cord and plug provided with pump is
intended to be used with mating spa pack connector.
9. Improper grounding can cause serious injury and damage to the motor, voiding the warranty.
10. If the supply cord is damaged, it must be replaced by a special cord or assembly available from the manufacturer
or its service agent.
IMPORTANT SAFETY INSTRUCTIONS & WARNINGS • SAVE THESE INSTRUCTIONS • PLEASE READ AND FOLLOW ALL INSTRUCTIONS
Ensure wiring circuit agrees with diagram and leads are securely tight.
For Wiring Instructions
Refer to Wiring Diagram on Motor.
810-0061.0117
©2017 Waterway Plastics
2200 East Sturgis Road, Oxnard CA 93030 • Phone 805.981.0262 • Fax 805.981.9403
www.waterwayplastics.com • waterway@waterwayplastics.com
Designed,
Engineered &
Manufactured
in the USA.
WARRANTY
For product registration visit: www.waterwayplastics.com.
For Warranty questions or claims please contact point of purchase.

Questions and Answers:

Waterway 48 Frame Power Defender Executive Specifications

General IconGeneral
Voltage230V
Frame Size48 Frame
Speed3450 RPM
Warranty1 year
Amperage (High)12.0A
Amps16.0/8.0 A
Max Head42 ft

Summary

General Safety and Installation Instructions

Pump Connections Installation

Details on pump placement, ensuring a level surface below water level with proper drainage and union connections.

Motor Wiring Safety and Procedures

Highlights safety precautions for electrical connections, emphasizing qualified electricians, correct wiring, and grounding.

Troubleshooting Guide

Motor Won't Start

Diagnoses issues for motors that hum but won't start, checking voltage, connections, and thermal protectors.

Motor Noisy

Addresses motor noise by checking mounting security, bearing noise, or rotor rubbing for potential service.

Pump Runs, Then Stops

Troubleshoots pumps that stop by checking motor overload via amp draw or potential internal binding.

Pump Runs, No Flow

Identifies causes for no flow, such as closed valves, pump being above water level, or air locks.

Pump Runs, Not Enough Flow

Explains insufficient flow due to partially closed valves or a dirty impeller or filter.

Assembly Drawing and Parts

Exploded View

Provides a visual breakdown of the pump components, including the volute, impeller, seal, and motor.