10 www.wavetronix.com
SmartSensor HD
When lanes have variable widths or have variable spacing (e.g. gore between lanes), precise resolution is necessary.
12.3 Windows®–based Software. e RVSD shall include graphical user interface software that displays all congured
lanes and the current trac pattern using a graphical trac history representing at least the last 1.5 seconds of detected
trac. is graphical trac history shall also allow the option of displaying the measured speed or length of a detected
vehicle.
A visual representation of trac patterns allows an installer to quickly associate specic detections with corresponding vehicles, and it
facilitates verication of RVSD performance.
e graphical interface shall operate on Windows Mobile, Windows XP, Windows Vista, and Windows 7 in the .NET
framework.
e software shall support the following functionality:
• Automatically nd the correct baud rate
• Automatically nd the correct serial communication port
• Operate over a TCP/IP connection
• Give the operator the ability to save/back up the RVSD conguration to a le or load/restore the RVSD congura-
tion from a le
• Provide a virtual connection option so that the software can be used without connecting to an actual sensor
13.0 Operating Conditions. e RVSD shall maintain accurate performance in all weather conditions, including rain, freezing
rain, snow, wind, dust, fog and changes in temperature and light, including direct light on sensor at dawn and dusk.
RVSD operation shall continue in rain up to 2 in. (5.08 cm) per hour.
e RVSD shall be capable of continuous operation over an ambient temperature range of -40°F to 165.2°F (-40°C to 74°C).
e RVSD shall be capable of continuous operation over a relative humidity range of 5% to 95% (non-condensing).
14.0 Testing.
14.1 FCC. Each RVSD shall be certied by the Federal Communications Commission (FCC) under CFR 47, Part 15,
section 15.249 as an intentional radiator.
e FCC certication shall be displayed on an external label on each RVSD according to the rules set forth by the FCC.
e RVSD shall comply with FCC regulations under all specied operating conditions and over the expected life of the
RVSD.
14.2 NEMA TS 2-2003 Testing. e RVSD shall comply with the applicable standards stated in the NEMA TS 2-2003
Standard. ird-party test results shall be made available for each of the following tests:
• Shock pulses of 10 g, 11 ms half sine wave
• Vibration of 0.5 g up to 30 Hz
• 300 V positive/negative pulses applied at one pulse per second at minimum and maximum DC supply voltage
• Cold temperature storage at -49°F (-45°C) for 24 hours
• High temperature storage at 185°F (85°C) for 24 hours
• Low temp, low DC supply voltage at -29.2°F (-34°C) and 10.8 VDC
• Low temp, high DC supply voltage at -29.2°F (-34°C) and 26.5 VDC
• High temp, high DC supply voltage at 165.2°F (74°C) and 26.5 VDC
• High temp, low DC supply voltage at 165.2°F (74°C) and 10.8 VDC
15.0 Manufacturing. e RVSD shall be manufactured and assembled in the USA.