SmartSensor HD
7
• 4X corrosion protection (NEMA 250 clause 5.10)
• Gasket (NEMA 250 clause 5.14)
e RVSD shall be able to withstand a drop of up to 5 ft. (1.5 m) without compromising its functional and structural
integrity.
e RVSD enclosure shall include a connector that meets the MIL-C-26482 specication. e MIL-C-26482 connector
shall provide contacts for all data and power connections.
7.0 Power. e RVSD shall consume less than 9.5 W.
e RVSD shall operate with a DC input between 12 VDC and 28 VDC.
8.0 Communication Ports. e RVSD shall have an RS-485 port and an RS-232 port, and both ports shall communicate inde-
pendently and simultaneously.
e two simultaneous ports are necessary whenever simultaneous access to the RVSD is needed or redundancy is required. For example, two
ports are needed if event data and interval data must be collected at the same time. For an example of redundancy, the RS-232 port and
RS-485 port could each be connected to separate communications device to provide a backup means of communication in case a device fails.
e RS-232 port shall be full-duplex and shall support true RTS/ CTS hardware handshaking for interfacing with various com-
munication devices.
e RVSD shall support the upload of new rmware into the RVSD’s non-volatile memory over either communication port.
e RVSD shall support the user conguration of the following:
• Baud rate
• Response delay
• Data push
• RS-232 ow control (RTS/CTS or none)
e communication ports shall support all of the following baud rates: 9600, 19200, 38400, 57600 and 115200 bps.
9.0 Data Protocols. e RVSD shall support three dierent data protocols for all lanes being monitored: interval (bin) data, event
(per vehicle) data, and real-time true presence data.
e RVSD manufacturer shall provide the data protocol document free of charge.
e interval (bin) data packet protocol shall support:
• Sensor ID
• A timestamp that records the year, month, day, hour, minute, and second of the end of time interval
• Total volumes of more than 65536
• Average speed values in either mph or kph
• Occupancy in 0.1% increments
• Volume in up to eight length-based user-dened vehicle classication bins
• Volume in up to 15 user-dened speed bins (bin by speed)
• Volume for both directions of trac (bin by direction)
• Average headway in seconds
• Average gap in seconds
• 85th percentile speed in either mph or kph
e event (per vehicle) data packet protocol shall support:
• Sensor ID