ABOVE GROUND – PUMP REMOVAL
Figure E - Above Ground Pump Removal
(top view)
Disconnect power to pump. Using the included 25 ft. rope, safely
pull pump to edge of pool, disconnect discharge hose and remove.
Do NOT handle pump with wet hands or when
standing in water or on a damp surface when the unit is operating
or fails to operate. ALWAYS disconnect pump power cord from power
source before handling. Do NOT bury cord. Visually locate cord to
prevent damage caused by lawn mowers, hedge trimmers
and other equipment. Failure to do so WILL result in fatal
electrical shock.
NE PAS manipuler la pompe avec
les mains humides ou debout dans l’eau ou sur une surface humide
lorsque l’appareil fonctionne ou ne fonctionne pas corectement.
TOUJOURS débrancher le cordon d’alimentation de la pompe de la
source de courant avant toute manipulation. Ne PAS enterrer le cordon.
Repérer visuellement le cordon pour éviter les dommages causés par
les tondeuses à gazon, les taille-haies et autres équipements. Ne pas le
faire ENTRAÎNERA un choc électrique mortel.
7. The water level must be at least 2-1/8 inches for the pump to
cycle, prime, and operate. Water levels less than 2-1/8 inches will
not allow the impeller to contact water therefore no water will be
pumped.
8. Plug the pump into a properly grounded 120 volt GFCI protected
outlet. The pump will start automatically when the water reaches
a depth of 2-1/8 inches. A priming delay of 2 seconds is
programmed into the control to allow time for air to escape from
the pumping chamber.
9. The pump will stop automatically once water has been removed
to a depth of approximately 3/4 of an inch. The pump will not
restart until the water depth rises to 2-1/8 inches or greater.
10. The pump will not allow itself to run dry. Once the pump
detects that water is no longer being removed, it will shut down
automatically. The pump must remain upright at all times in
order for the water detection to function. Do not allow the pump
to operate on its side or inverted The shaft seal depends on
water for lubrication, allowing the pump to remain in any other
orientation than upright could cause shaft seal failure or pump
failure.
Do not alter the pump to override the automatic
water detector. The shaft seal depends on water for lubrication.
Overriding this pump feature can cause the pump to run dry and may
damage the shaft seal and cause pump failure, and will void warranty.
Pump starts automatically. Always disconnect
electric supply before attempting to install, service, relocate, or perform
any maintenance.
La pompe démarre automatiquement. Toujours
couper le courant avant d’essayer d’installer, de réparer, de déplacer ou
d’effectuer toute opération de maintenance.
NOTE: Minimal service is required for this pump. The motor housing
of the pump is completely sealed and requires no internal service or
lubrication.