4 Installation instructions CC8 roof-top air-conditioning system
416
4.10.4 Assemble the air distribution panel
NOTE
Depending on the version and the components supplied, the rocker switches and, if
applicable, the setpoint generator switch may have to be installed in the air distribution
panel.
Fig. 409 Air distribution panel, assembly
1. Insert the rocker switches in the rectangular cut-outs in the air distribution panel so that they engage.
(see Fig. 409).
2. Insert the setpoint generator switch into the hole in the air distribution panel as shown in Fig. 409.
NOTE
The wiring harness is (mechanically) prepared for connection to the setpoint generator
potentiometer. Simply pull on connector housing to unplug the connector. The
connector housing can be locked (self-locking action) by simply pulling on the wiring
harness. The fibre optic cable must be in contact with the rotary knob.
Rocker switches
Setpoint generator
switch
(temperature control)
Correct.
Incorrect
Air distribution panel