CC8 roof-top air-conditioning system 4 Installation instructions
415
4.10.3 Install the base frame
1. Remove the cover from the air-conditioning unit.
2. Position the base plate on the roof with the weatherseal, align it and position spacer discs underneath the six fixing
points. Place six M8 bolts with washers in the holes (see Fig. 408).
Fig. 408 Installation of the base plate
3. Check that the base plate is in the correct position and secure it uniformly using the washers, and nuts supplied in
the installation kit (tightening torque 15 Nm).
4. The tightening torque for the self-tapping screws must be such that it does not damage the air distribution panel
and mounting points.
5. Route refrigerant hoses, electric cables and condensation hoses as shown in 4.12 and 4.13.
Armaflex/Eurobatex
dirt protection strip
Sheet metal screw
Air distributor panel
Hex nut
DIN 985 M8
Distance
piece
Intermediate ceiling
Optional circulating
air filter with screen
Hex screw
DIN 7985 M8x55
Washer
DIN 9022-B8.4
Washer
DIN 125-B8.4
View from below
Condensation water drain
Armaflex/Eurobatex
sealing frame
Air duct
sealing