NOTE
If the heater is activated by the switch, the types of malfunctions are indicated by
coded flashing signals via the operation indicator light during the run-on time of
the heater.
After five short signals, count the long flashes:
The flashing pulses match the number in the table below.
F 00/-- (only five short flashing pulses)
Heater lock-out or control unit defective,
Unlocking only possible by specialised workshop
F 01 No start (after 2 starting attempts)
F 02 Flame failure
F 03 Undervoltage or overvoltage
F 04 Premature flame detection
F 05 Flame monitor interruption or
flame monitor short circuit
F 06 Temperature sensor interruption or
temperature sensor short-circuit
F 07 Metering pump interruption or
metering pump short-circuit
F 08 Fan motor interruption or
fan motor short-circuit or
incorrect fan motor speed
F 09 Glow plug interruption or
glow plug short circuit
F 10 Overheating
F 11 Circulation pump interruption or
circulation pump short circuit