2608C.p65 30 ?2009/6/5, 下午 04:18
30
9427370000_00/06.2019
SPECIFICATIONS
·
Display: 6600 counts, 66 segments analog bar-graph.
·
Polarity: Automatic, (-) negative polarity indication.
·
Overrange Indication: (OL) or (-OL) is displayed.
·
Low Battery Indication: The " " is displayed when the battery
voltage drops below accurate operating level.
·
M easurement Rate: 2.8/sec, nominal. 28/sec, Analog bar-graph.
·
Operating Environment: 0°C to 50°C at < 70% R.H.
·
Storage Environment: -20°C to 60°C at < 80% R.H.
·
Temper ature Coefficient: 0.1 × (specified accuracy) / °C (< 18
°C
or > 28
°C).
·
Auto Power Off: 30 minutes after rotary switch or mode changes.
·
Altitud e: 6561.7 Feet (2000m)
·
Power: Standard 9-volt battery, NEDA 1604, IEC 6F22, JIS 006P.
·
Battery Life: 75 hours typical with carbon-zine battery.
·
Jaw Opening Capability: 57mm conductor, 70 × 18mm bus bar.
·
Size (H × W × D): 11.1 × 4.3 × 2.1 inches (281 × 108 × 53 mm).
·
Weight: Approx. 20.1 OZ/570g grams (including battery)
Acc
uracy is given as
±
([% of
reading]+[number
of least
significant
digits]) at 18°C to 28°C, with relative humidity up to
70%.