© weinor GmbH & Co. KG 4 | EN
5. Press the UP button at the device immediately after the
start of upward travel. The drive will stop brie y.
6. Press the DOWN button at the device immediately after the
start of downward travel. The drive will stop.
You have successfully programmed the device.
Symbols at the device
Alarm LED (red)
Light LED (yellow)
Operating LED (green)
Wind
Rain
Twilight
DOWN
button
UP
button
STOP /P
button
/P
Setting the threshold values
There are rotary potentiometers at the underside of the
device. You can set the threshold values in steps using the
rotary potentiometers.
Light
OFF The light function is switched off
Level 1 Travel down at a low light level
Settings 2
to 14
Intermediate levels
Level 7
Factory setting
Level 15 Travel down at a high light level
Wind
Level 1 Travel up at low wind speed
Settings 2
to 10
Intermediate levels
Level 4
Factory setting
Level 11 Travel up at high wind speeds
Rain
OFF The rain function is switched off
Level 1 Travel up at a low rain level
Settings 3
to 14
Intermediate levels
Level 15 Travel up at a high rain level
Level 2
Factory setting
(BiSens SWR-230V)
Twilight
OFF The twilight function is switched off
Factory setting
Level 1 Travel down at darkness
Settings 2
to 13
Intermediate levels
Level 14 Travel down at start of twilight
Note
The factory settings for OEM devices may differ from the
above.
LED ash signals
Light LED (yellow)
shines
Light value reached or exceeded, or twilight
value reached or undercut
Light LED (yellow)
ashes constantly
Flashes for the duration of the delay time:
light value undercut
Alarm LED (red)
shines
Measured wind value or rain value reached
or exceeded
Alarm LED (red)
ashes constantly
Delay time. Wind value or rain value under-
cut
Operating LED
(green) goes out
once
Device transmits in awning mode
Operating LED
(green) goes out
twice
Device transmits in protection against prying
eyes mode
Operating LED
(green) goes out 3x
Device transmits in roller shutter mode
All LEDs ash A sensor is defective or wet
Light function
The light intensity is measured by the integrated light sensor
and compared to the threshold value.
Requirement
The blind is raised.
min.
5 - 7 min.
The sun shines on the sensor for no less than 5 to 7 minutes.
The measured light value reaches or exceeds the set
threshold value.
The yellow light LED lights up.
After a short delay (5 to 7 minutes), the blind will travel down.
The weather situation is changing.
The measured light value falls below the set threshold value.
P