Heating System Tempura | Système de chauffage Tempura – Instructions for assembly, maintenance and use |
Notice de montage, instructions d’entretien et d’utilisation Version | Version 05.08.2019
Reserve technical changes | Sous réserve de modifications techniques Item no. | N° art. 115727-0000 Page | Page 17/20
Notice de montageAssembly instructions
9. Fault analysis 9. Analyse des défauts
Fault Cause Remedy
The heating element is not Unit is switched off. Switch unit on.
producing any heat.
The fuse or trip switch has been Check the fuse and make sure that no
activated. other heavy duty consumers are
connected through the same fuse.
Halogen infra-red heating element Replace heating element.
is faulty.
Type de défaut Cause possible Solution
Le radiateur ne dégage pas de chaleur. L’appareil est éteint. Mettre en marche l’appareil.
Le fusible ou le disjoncteur différentiel Vérifier le fusible et veiller à ce qu’aucun
a sauté. autre appareil puissant ne soit branché
sur le même fusible.
Le radiateur halogène infrarouge est Remplacer le radiateur.
défectueux.