Installation and operating instruction
Hydraulic unit WWP LS 8 ... 16-B
83306902 2/2017-05

Table of Contents

Questions and Answers

  • J
    Jose SmithAug 7, 2025
    What to do if pressure downstream of compressor is too high in Weishaupt Heat Pump?
    • S
      Sandra SmithAug 7, 2025
      If the pressure downstream of the compressor is too high in your Weishaupt Heat Pump, it is recommended to check the refrigerant level, inspect the actuator of the expansion vessel (replacing if necessary), and examine the service valves.
  • D
    dcooperAug 11, 2025
    What to do if pressure upstream of heat exchanger in outdoor unit is too low in Weishaupt Heat Pump?
    • W
      William WongAug 11, 2025
      If the pressure upstream of the heat exchanger in the outdoor unit is too low in your Weishaupt Heat Pump, you should check the refrigerant level and the soundness of the cooling circuit. Also, inspect the actuator of the expansion vessel and replace it if necessary.
  • C
    Cory AnthonyAug 15, 2025
    What to do if air intake sensor (OAT) is defective in Weishaupt WWP LS 8-B R-E HE Heat Pump?
    • C
      Cynthia SnyderAug 15, 2025
      If the air intake sensor (OAT) is defective in your Weishaupt Heat Pump, check the sensor and cable, and replace them if necessary.
  • K
    Kimberly SchwartzAug 20, 2025
    What to do if heat exchanger sensor OU inlet (OCT) is defective in Weishaupt WWP LS 8-B R-E HE?
    • M
      Michael CollierAug 20, 2025
      If the heat exchanger sensor OU inlet (OCT) is defective in your Weishaupt Heat Pump, check the sensor and cable, and replace them if necessary.
  • B
    Brooke KingAug 25, 2025
    What to do if heat exchanger sensor OU centre (OMT) is defective in Weishaupt Heat Pump?
    • J
      Joshua PhelpsAug 25, 2025
      If the heat exchanger sensor OU centre (OMT) is defective in your Weishaupt Heat Pump, check the sensor and cable, replacing them if necessary.
  • G
    Gary RollinsAug 28, 2025
    What to do if compressed gas temperature sensor (CTT) is defective in Weishaupt WWP LS 8-B R-E HE Heat Pump?
    • R
      Ronald McdonaldAug 28, 2025
      If the compressed gas temperature sensor (CTT) is defective in your Weishaupt Heat Pump, check the sensor and cable, and replace if necessary.
  • K
    karabellSep 2, 2025
    What to do if temperature sensor in inverter (HST) is defective in Weishaupt WWP LS 8-B R-E HE Heat Pump?
    • C
      Cynthia NormanSep 2, 2025
      If the temperature sensor in the inverter (HST) is defective in your Weishaupt Heat Pump, check the sensor and cable, and replace them if needed.