Capacity
Electrical specifications
Water
C4eT 6.20 GB-N
3
Loading capacity
Max. number of food containers
[Unit has 7slide rails; rail spacing 2.68" max.]
Steam table pans (12"x20"x1") 12
Steam table pans (12"x20"x2.5") 12
Wire shelves, full size (20"x26") 6
Sheet pans, full size (18"x26")* 6
Sheet pans, half size (12"x20")* 12
Frying baskets, half size (12"x20") 12
Plates (optional plate rack) 27
Max. loading weight
Per combi oven 132 lbs
Per shelf level 33 lbs
* Wire shelves required.
Electrical supply
120V 1PH 60Hz *
Rated power consumption 0.6 kW
Rated current 7.5 A
Power supply wire gauge 14 AWG
Conductor insulation rating 194°F / 90 °C
* Prepared for connection to an energy optimizing system.
Electrical supply must be connected to dedicated permanent supply line. Any
Ground fault or residual current protection must be rated at least 20mA. Do not
connect to residential GFI receptacles as they will cause nuisance trips of the
device.
Water connections
Water supply
Water supply Two 3/4'' inner diameter GHT-M
(garden hose adapter needed)
or
Two hoses 1/2" inner diameter with
one siede 3/4" GHT-F to 3/4" BST (no
adapter needed)
The unit is designed for a
permanent hookup to the water
supply that uses a connecting hose
with a minimum diameter of 1/2".
Flow pressure 22 - 87 psi / 1.5 - 6 bar
Drain
Drain version Permanent hookup (recommended)
or funnel waste trap
Type 2" inside diameter (comes elbow-
shaped as standard)
Slope for drainpipe min. 3.5% (2°)
Water quality
Water connection A* for boiler,
Water connection B* for cleaning, recoil hand shower
General requirements Drinking water, typically untreated
water
TDS 70 - 360 ppm
Hardness 70 - 360 ppm (4 - 21 gpg)
pH value 6.5 - 8.5
Cl
-
(chloride) max. 60 ppm
Cl
2
(free chlorine) max. 0.2 ppm
SO
4
2-
(sulfate) max. 150 ppm
Fe (iron) max. 0.1 ppm
SiO
2
(silica) max. 13 ppm
NH
2
Cl (monochloramine) max. 0.2 ppm
Temperature max. 104°F / max. 40°C
* See connection positions diagram, p. 2.
NOTICE: The owner/operator/purchaser must ensure that the water quality
requirements are met. Otherwise the original equipment warranty is void.