Error messages and error clearance
Message/symptom Possible cause Remedial measures
Extraction power missing Pipesystemleaking Resealthepipesystem
Filterisdirty changethelter
Zero Smog is not running Thermallyswitchedoff Leave the Zero Smog to cool
down Switch on again afterap-
prox. 3 hours
Sub-micron paricle
becomingdirtytoquickly
Pre-lterhasnotbeenused Useapre-lterFitanM5lter
Useapreliminaryseperatorifthe
proportion of solid matter is high.
Toensurethattheltrationsystemfunctionsproperly,thecompact
ltermustbereplacedasfollows
atleastonceayearor
if the maximum allowable workplace concentration is exceeded or
as per maintenance schedule
Thesuspendedmatterlterandthebroadbandgaslterarecomple-
mentarytooneanotherandcanbereplacedtogetherasacompact
lter.Thecompactltermustbechangedonceayearinorderto
ensureitisfullyfunctional.Thenedustlter(ltermat)isthepre-
liminarystageofthecompactlterandthereforemustbereplaced
morefrequently.
Itisstronglyrecommendedthatthecompactlterbereplacedafter
nomorethan10nedustlterchanges.
The red warning light is ashing:
Recommendedservicelifeoflterhasexpired.Indicatesthatthe
lterneedschanging.Resetthewarningwiththeresetfunctionon
thecontrolpanelandschedulealterchange.
The red warning light is lit continuously:
Extractioncapacityistoolow.Switchoffthelterunit.Checkthe
nozzlesandtubes,andcleanthemifnecessary.Iftheredwarning
lightcomesonagainthenexttimetheunitisturnedon,thelter
must be changed.
Ifnoactionistaken,thelterunitwillcutoutafterveminutesin
order to avoid overheating.
Whenchangingthemainltertheltrationtimecanberesetas
follows:.
Holdthefanbuttondownand,atthesametime,turnontheswitch
untiltheredwarninglightashesfor3sec.
Care and maintenance
Warning!
Before doing any work on
the machine, pull the plug
out of the socket.
Use original replacement
parts only.
Contaminated lters must be
treated as special waste.
Dispose of replaced equip-
ment parts, lters or old
devices in accordance with
the rules and regulations
applicable in your country.
Notice
Different uxes and ux
constituents and the amount
of and size of dust particles
in the extracted air will signi
cantly effect the lters wor-
king life. Submicron particles
in the extracted air increase
when soldering or welding to
varnish insulated wire.