16
GB
Technical Data
Solder fume extraction Zero Smog EL
Dimensions L x W x H (mm) 335 x 360 x 445
Dimensions L x W x H (inch) 13.19 x 14.17 x 17.52
Weight approx. (kg) 8,6
Mainssupplyvoltage (V/Hz) FT91010699:
230/50
Zero Smog EL
120/60
Power consumption (W/V) 110/230
95/120
Maximum vacuum (Pa/V) 2.500/230
2.100/120
Maximumquantitysupplied (m³/h) 150
Prelter
MediumlterM5collects40-60%nedust>1mm.
Combinedlter CombinedH13highefciencysubmicronlter(99.95%
particleseparationupto0.12μm)
incombinationwithanactivatedcarbonlter
Original declaration of conformity
Solder fume extractor Zero Smog EL
Weherebydeclarethattheproductsdescribed
hereincomplywiththefollowingguidelines:
2011/65/EU(RoHS),2014/30/EU,2006/42/EG
Applied harmonised standards:
EN 60 335-1: 2012-10
EN 60 335-2-45: 2012-08
EN62233:2008-11/2009-04
EN 55 014-1: 2012-05
EN 55 014-2: 2009-06
EN 61 000-3-2: 2015-03
EN 61 000-3-3: 2014-03
EN 50 581: 2013-02
Besigheim,2015-10-13
B.Frühwald T. Fischer
Managing director Technical director
Authorised to compile technical documentation.
WellerToolsGmbH
Carl-Benz-Straße2,74354Besigheim,Germany
Symbols
Caution!
Read the operating instructions!
Beforeperformingworkofanykind
ontheunit,alwaysdisconnectthe
power plug from the socket.
ESD-compatible design and
ESD-compatible workstation
CEmarkofconformity
Disposal
Do not dispose of electric tools together
with household waste material! In obser-
vanceofEuropeanDirective2012/19/EU
onwasteelectricalandelectronicequip-
ment and its implementation in accordance
withnationallaw,electrictoolsthathave
reached the end of their life must be collec-
tedseparatelyandreturnedtoanenviron-
mentallycompatiblerecyclingfacility.
Contaminatedltersmustbetreated
as special waste.
Disposeofreplacedequipmentparts,lters
or old devices in accordance with the rules
andregulationsapplicableinyourcountry.