Installation Guide04
07
It is very important to follow all instructions listed. Failure to do so may cause
the system to not operate properly and may impact the long term reliability of
the system.
1. Check incoming water pressure and insure it is between 60-70PSI. If the
water pressure is above 70PSI then a pressure reducing valve must be installed
and set to lower the pressure to the optimal water pressure between 60-70PSI.
a. Failure to follow this step may have a negative impact on the reliability
of the system and may cause it to failure prematurely.
b. Failure to follow this step may also affect the taste of the ice and
water along with the replenishment rate of the ice.
c. Failure to follow this step may also impact the life of the filters in a
negative way
d. Failure to follow this step may also cause a leak or similar failure.
2. Flush the filters
a. Remove the filter enclosure from the box and visually inspect all
fittings
- You will notice that the RO membrane is not connected, this is shipped
this way to ensure the preservative remain inside the filter to protect the
membrane
b. Flush the Pre-Sediment and Pre-Carbon filters for 5 minutes
- Connect the source line into the input of the Pre-Sediment and a drain
to the output of the Pre-Carbon.
i c. Turn the water on for 5 minutes then turn the water off.
- Remove the source and drain and reconnect the pre-existing
connections
d. Flush the Bio Sure Plus filter for 5 minutes
- Connect the source line into the input of the Bio Sure Plus filter
e. Connect the drain into the output of the Bio Sure Plus filter
- Turn the water on for 5 minutes and then turn the water off
f. Remove the source and drain and reconnect the pre-existing
connections
g. Reverse Flush the TCR Carbon Post filter
- Connect the source line into the output of the TCR filter
- Connect the drain into the input of the TCR Filter
h. Turn the water on for 5 minutes and then turn the water off
- Remove the source and drain and reconnect the pre-existing
connections
i. Flush all 5 filters together
- Connect the loose fittings to the RO