GREASING THE VIBRATING ASSEMBLY
11. Use the 6mm hex wrench to remove the socket-head cap screw and washers from the right side of the
vibrating assembly (Figs. 11, 12). It’s a standard right-hand threaded screw (lefty-loosey).
Fig. 11: Use a 6mm hex wrench to remove this screw. Fig. 12: Screw and washer removed.
12. Slide the pulley off the assembly, as well as the shaft key (Figs. 13, 14).
Fig. 13: Pulley removed. Fig. 14: Shaft key removed.
13. Remove the retaining ring and eccentric block (Figs. 15 – 17).
Date last modified: 2023/01/30