FUEL OPTION B: LIQUID PETROLEUM GAS (LPG)
To connect your generator to an LPG cylinder:
1. Take off the safety caps from the cylinder valve, genera-
tor mounted regulator, and regulator connecting hose ends.
2. With the LPG tank valve closed, attach the LPG regulator
connecting hose (Fig. 5 - 1) to the valve. Turn the plastic
coupling from the hose right (clockwise) to tighten hose
assembly onto the LPG tank.
3. Remove the protective cover from the LPG inlet (Fig. 6 -
1) on the generator. Push the connector on the other end of
the regulator hose into the LPG inlet until it clicks into place.
4. Turn the LPG tank valve ON and check for leaks by spray-
ing soapy water to check connections. If bubbles appear,
become larger in size, or increase in number, a leak exists.
This MUST be corrected before using generator. Contact
WEN customer service at 1-847-429-9263, M-F 8-5 CST, or
email techsupport@wenproducts.com for assistance.
NOTE: If you would like to purchase other accessories for
your dual-fuel generator, consult your local dealer of pro-
pane and propane accessories, I tell you what.
Fig. 5
Fig. 6
1
1
CAUTION! Always position the LPG cylinder so the connection between the tank and LPG inlet won’t cause
sharp bends or kinks in the hose.
WARNING! Risk of burns. Contact with liquid contents of cylinder will cause freeze burns to the skin. If liquid
contents contacts skin or eyes, seek immediate medical attention.
WARNING! When transporting and storing, keep cylinder secured in an upright position with cylinder valve
turned off. Keep cylinders ventilated and away from heat when in a vehicle.
PREPARATION