P1PY1xx
Long-Range Laser Distance Sensors
der wintec.

Questions and Answers

  • J
    jeffreythomasAug 7, 2025
    What to do if my Wenglor P1PY108 Security Sensors shows an error?
    • S
      Sabrina MooreAug 7, 2025
      If your Wenglor Security Sensor indicates an error, it might be due to a short circuit. Inspect the wiring and correct any shorts. Alternatively, the sensor may be overheating. If this is the case, disconnect it from the power supply and let it cool down. A device error could also be the cause. Try disconnecting and then reconnecting the sensor to restart it. If the problem persists, consider replacing the sensor.
  • M
    Monica JeffersonAug 23, 2025
    Why is my Wenglor P1PY108 showing a warning?
    • A
      allenjaneAug 23, 2025
      A warning signal may indicate that the distance between the sensor and the object is too great. Try reducing this distance. Alternatively, undervoltage could be the cause. Ensure the voltage supply is at least 18 V DC.

Summary

Operating Instructions

General Information

Product Safety Precautions

Intended Use Guidelines

Specifies the functional principle and applicable industry sectors for the sensors.

Warnings Against Unintended Use

Highlights risks and restrictions associated with using the product outside its intended purpose.

Prohibition of Product Modification

States that product modifications are forbidden and will void the warranty.

General Safety Measures

General safety guidelines for handling, protection, and reading instructions.

Laser and LED Safety

Information on laser class compliance and observance of safety regulations.

Technical Data Specifications

Installation and Electrical Connection

Sensor Mounting and Installation

Steps and precautions for mechanically mounting the sensor securely.

Electrical Connection Procedures

Instructions on wiring the sensor according to connection diagrams.

Sensor Configuration and Settings

Settings for Switching Output Models

Describes teach-in modes for sensors with digital switching outputs.

Settings for Analog Output Models

Explains analog output functions and characteristic curve setting.

IO-Link Communication and Configuration

IO-Link Parameter Settings

Details functions configurable via IO-Link parameters.

wTeach2 Configuration Software

Wenglor P1PY108 Specifications

General IconGeneral
Housing MaterialPlastic
Protection ClassIP67
Operating Voltage10-30 V DC
Switching OutputPNP
Output Current100 mA
Connection TypeM8 connector
Ambient Temperature-25°C to +55°C
Operating Temperature-25°C to +55°C