5. Operation with COM Port
5.1 Settings
For the COM port you need the following settings:
Baud rate 9600 bits per second
Data bits 8
Stop bit 1
Parity None
Flow control No
5.2 Commands
Note: Every command has to end with a return or line feed.
5.2.1 Version
Type Command Description
Version
V Information about the version.
V<CR>
Return
Information of the version
Example:
V<CR> Version:1.2.0
5.2.2 Name
Type Command
Description
Name N Information about the name.
N<CR>
Return
Information of the name
Example:
N<CR> USB TERMINAL ELEMENT