SERVICE BULLETIN
DATE:
December
8,
1983
BULLETIN
NUMBER:
130
MODEL:
W50
SUBJECT:
On
Engine
Fuel
System-
Bleed
Procedure
(REFER
TO
THE
ILLUSTRATION
WHEN
FOLLOWING
THE
PROCEDURE
BELOW)
1. After
air
has
been
bled
from
that
portion of the fuel system
between
the
fuel tank
and
engine, the
use
of the
manual
primer
on
the fuel
lift
pump
can
aid in accomplishing
this,
proceed to bleed point
#1
with a
5/8"
box
wrench.
Loosen
this
banjo
bolt
1 - 2 turns.
(Do
not
remove
the
bolt
from
the
filter.)
Work
the
manual
priming lever
on
the fuel
lift
pump
and
purge
all
air
out of the secondary
filter
until
fuel
free of
air
bubbles flows
from
around
this
banjo
bolt.
Once
fuel free of
air
flows
from
around
the
bolt,
retighten the
bolt.
NOTE
#1:
You
may
want
to
place a small
plastic
garbage
bag
around
and
under the secondary
filter
with a
few
paper towels to catch the
fuel.
NOTE
#2:
When
working
the
manual
priming lever
on
the fuel
lift
pump,
move
it
with
long
and
deliberate
strokes -
NOT
rapidly.
In
some
rare instances, the
lift
pump
may
internally
be
at
or near the
maximum
pump
stroke
and
no
pumping
action will
be
achieved using the
manual
external priming
lever,
making
it
necessary
to turn the engine over
slightly
with the
starter
to reposition the
pump
internally.
2.
With
the aid of a 5/16"
box
wrench, or socket (1/4" Drive),
open
the
bleedscrew
#2
on
the side of the fuel
injection
pump,
1 or 2
turns.
DO
NOT
remove
the screw.
Again
work
the
manual
priming lever
on
the
engine-mounted fuel
lift
pump;
purge
all
air
from
this
area of the
fuel injection
pump
and
when
fuel free of
air
flows, retighten the
bleedscrew
#2.
NOTE:
Models
with pushbutton
starting
refer
to the
inset
for point
#2A
located
on
the fuel pressure switch
manifold
mounted
at
bleed point
#2
on
the
injection
pump.
Bleed
#2A
as above.
3.
With
the aid of 5/16"
box
wrench
or socket (1/4" Drive)
open
the
bleedscrew
#3
and
bleed
this
portion of the injection
pump
as in
Step
#2.
NOTE:
PIN:
33547
Ensure
that
the
throttle
is
full
open
and
the engine
shut-off lever
is
in the
RUN
position
when
proceeding
to
Step
#4.
over
.......
.
J. H. WESTERBEKE CORP.
AVON
INDUSTRIAL
PARK,
AVON,
MASS.
02322·
(617/588-7700
CABLE:
WESTCORP,
AVON·
TELEX:
fl2-
••••

Other manuals for Westerbeke 50