OWNER’S MANUAL
MANUEL DE L’UTILISATEUR
UNDER CABINET RANGE HOOD
HOTTE DE CUISINIÈRE POUR DESSOUS DARMOIRE
# QR088 / 12345019
# QR089 / 12345020

Questions and Answers

  • Q
    qrodriguezAug 10, 2025
    Why is my Westinghouse QR088 Ventilation Hood not venting properly?
    • R
      Rebecca JonesAug 10, 2025
      Several factors can cause this. First, ensure that no birds or animals have nested in the duct. The distance between the cooktop and the bottom of the hood should be between 458 mm (18 in) and 710 mm (28 in). Ductwork should follow all requirements, using round metal duct work with a uniform diameter of 177 mm (7 in), and not exceed 35 ft (10.7 m). Reduce duct length and elbows if needed, and seal all joints properly. Also, make sure the duct doesn't open against the wind. For heavy cooking, use high speed and close nearby windows to prevent air gusts. Opening a window on the opposite side of the house can also improve performance.
  • E
    Erik ThorntonAug 15, 2025
    What to do if my Westinghouse QR088 Ventilation Hood is not operating?
    • M
      Miss Megan Thompson DDSAug 15, 2025
      First, check that the power supply cable and all electrical wiring are properly connected. Next, ensure that the power is turned on at the junction box or circuit breaker. Finally, verify that the wiring between the switch control and the control board are connected properly.
  • M
    mark68Aug 19, 2025
    Why is my Westinghouse QR088 vibrating when the fan is operating?
    • R
      Robin HernandezAug 19, 2025
      This could be due to a few reasons. Make sure the range hood is secured properly and tighten it if necessary. Also, check that the motor is secured in place and tighten it if needed. Finally, inspect the fan for any damage; if damaged, replace it.
  • J
    Jennifer IngramAug 25, 2025
    What to do if the lights work, but the fan is not spinning, is stuck, or is rattling in my Westinghouse QR088?
    • I
      ipowellAug 25, 2025
      The thermal protection system might be shutting the motor down because it's too hot. If this is the case, the motor should function properly after the system cools down, which usually takes about 10 minutes. Also, check to make sure that the fan isn’t jammed or scraping the bottom. If these steps don't resolve the issue, the motor might be defective and need to be replaced.
  • J
    Jonathon WatkinsAug 30, 2025
    Why do the fans seem weak on my Westinghouse Ventilation Hood?
    • D
      Dr. Stephen Rasmussen DDSAug 30, 2025
      Several factors could be causing weak fans. First, ensure that the duct size used is at least 177 mm (7 in) round, as insufficient duct size can affect performance. Next, check that the duct is not clogged with debris and that any tight mesh on the wall cap isn’t restricting airflow. Also, verify that the damper unit is opening properly and that no birds or animals have nested in the duct.
  • J
    Jessica ChristensenSep 3, 2025
    How to fix a light that does not work on a Westinghouse QR088 Ventilation Hood?
    • J
      Jessica AllisonSep 3, 2025
      The light bulb may be burnt out, so replace it. Also, check if the light bulb is loose and tighten it if necessary. If replacing or tightening the bulb doesn't work, remove the problematic bulb and insert a known working bulb to check if the light assembly is faulty. If the properly functioning light does not come on, the problem may be the light assembly and should be serviced or replaced.

Westinghouse QR088 Specifications

General IconGeneral
BrandWestinghouse
ModelQR088
CategoryVentilation Hood
Number of Fan Speeds3
Noise Level65 dB
Control TypePush Button
FinishStainless Steel
TypeRange Hood
Filter TypeAluminum Mesh
Ducting Diameter150mm