Command 35: Resetting coin meters in change giving tubes
Use this command when replacing token meter/emptying the
change tubes with machine off to synchronise with content of
change tubes.
Command 35 - press ENTER - display views
Code 0000 - enter 6203 - press ENTER
Command 36: Condition exact amount (no coins available for
change)
This command is for setting the number of coins below which the
machine will say "no coins available for change". The set value
must always account for the coin minimum in tubes. The tubes
that are not included in this condition must be set at "0". When
the contents drop below the minimum - the machine displays a
warning there are no coins available for change.
Command 37: Inhibits note validator during exact amount
Setting this command to 1 during exact amount will inhibit the
note validator. If only note validator installed - command has to
be set to 0.
Command 38: Emptying change giving tubes
This command is used to inventory the coins in the tubes of the
coin mechanism:
Command 38 - press ENTER - display views
Tube no. 00 - Enter 1 and press ENTER
Coin mech gives out coins from chosen tube until stop pressing
ENTER.