NOTE: All CAUTIONS and WARNINGS are identified by the symbol . All warnings are printed in bold capital letters.
WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING,
SPECIFYING OR APPLYING THIS PRODUCT. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS
COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION,
WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS.
WARNING: FOR ULC APPLICATIONS THESE APPLIANCES WERE TESTED TO THE OPERATING VOLTAGE LIMITS OF 20-31 VOLTS/
USING FILTERED (DC) OR UNFILTERED FULL-WAVE RECTIFIED (FWR). APPLY 80% AND 110% OF THESE VALUES FOR SYSTEM OPERA-
TION.
General Notes
• Strobes are designed to flash at 1 flash per second minimum over the Voltage Range.
• All candela ratings represent minimum effective Strobe intensity based on UL 1971.
• Series RSS & RSSP Strobe products are listed under CAN/ULC-S526-M87 for indoor use with a temperature range of 0° C to 49° C (32° F to
120° F) and maximum humidity of 93% (± 2%).
• All Canadian Installations should be in accordance with the Canadian Standard for the Installation of Fire Alarm Systems -
CAN/ULC-S524-01 and Canadian Electrical Code, Part 1.
rof)SPMA(tnerruCCLU:1elbaTtnuoMllaW-
SsetalPebortSPSSRdnaebortSSSRseire
egatloV
*tnerruCegarevA
CDV21roCDV42
@detaR
dc51dc03dc57dc011
CDV0.02060.290.561.022.
CDV0.42140.360.901.041.
CDV0.13330.740.180.001.
* Average Current per actual Wheelock
Production testing at listed VDC.
# U= FIRE/FEU lettering
Note: Models are available in either Red
or White.
Contact Customer Service for Order
Code and Delivery.
etalPebortSPSSRrofsrekaepS/selbiduA:3elbaT
tcudorPseireS
secnailppAenotitluMTM,TMA
snroHHN,HA
slleBrotoM01G/6
G-BM
srekaepS0707/5207E,0801/0701/0101-TE
semihC07HC
Note: Installation Instruction Sheets:
Series RSS/RSSP - Wall Mount
Multi-Candela (P83911); Series RSS
Ceiling Mount (P84025).
WARNING: FOR ULC APPLICATIONS THESE APPLIANCES WERE TESTED TO THE OPERATING VOLTAGE LIMITS OF 20-31 VOLTS/
USING FILTERED (DC) OR UNFILTERED FULL-WAVE RECTIFIED (FWR). APPLY 80% AND 110% OF THESE VALUES FOR SYSTEM
OPERATION.
25
rof)SPMA(tnerruCCLU:2elbaTtnuoMgnilieC
SsetalPebortSPSSRdnaebortSSSRseire
egatloV
*tnerruCegarevA
CDV21roCD
V42@detaR
dc51dc03dc57dc59
CDV0.02560.501.981.942.
CDV0.42540.070.911.951.
CDV0.13530.250.980.011.
)SPMA(tnerruCCLU:4elbaT
PWSSRseireSrof
egatloV
*tnerruCegarevA
CDV42@detaR
CDV0.02831.
CDV0.42490.
CDV0.13760.