12 | EN
the lower cover is opened or it is
located at the rear wall of the unit
depending on the unit type.
Power cable of your product must
comply with the values in "Technical
specifications" table.
DANGER
Risk of electric shock!
Before starting any work on the
electrical installation, please
disconnect the appliance from the
mains supply.
Connecting the power cable
1. If it is not possible to disconnect all
poles in the supply power, a
disconnection unit with at least 3
mm contact clearance (fuses, line
safety switches, contactors) must
be connected and all the poles of
this disconnection unit must be
adjacent to (not above) the product
in accordance with IEE directives.
Failure to obey this instruction may
cause operational problems and
invalidate the product warranty.
Additional protection by a residual
current circuit breaker is recommended.
If a cable is supplied with the
product:
2. For single-phase
connection,connect as identified
below:
Brown cable = L (Phase)
Blue cable = N (Neutral)
Green/yellow cable = (E)
(Ground)
3. For double-phase
connection,connect the wires as
identified below:
Brown cable = L1 (Phase 1)
Black cable = L2 (Phase 2)
Blue cable = N (Neutral)
Green/yellow cable = (E)
(Ground)
4. For three-phase connection,
connect the wires as identified
below:
Brown cable = L1 (Phase 1)
Black cable = L2 (Phase 2)
Black cable = L3 (Phase 3)
Blue cable = N (Neutral)
Green/yellow cable = (E)
(Ground)
Push the product towards the
kitchen wall.

Table of Contents