GENERAL INFORMATION
R600A Sealed System 2017
n
1-7
Tools & Supplies
Tools & Supplies
Vacuum Pump; Preferred to have a rating 6 CFM capacity
Gram measuring Scale
¼” High Pressure Hose
¼” Low Pressure Hose
Exclusive manifold gages and hoses should be
used for servicing R600a Appliances. (High, Low, and
Vacuum) Hose requirements for R600a are still being
defined.
Rubber Charging Hose with “T” Adapter & Shutoff Valve
20’ PVC Recovery Hose
R600a Refrigerant Maximum 420 Gram Cylinder
Piercing Pliers
Pinch Off Pliers
Tubing Cutters
Rubber Mallet
Certified and calibrated combustible gas leak detector to
test for leaks if the system is charged with an A2L or A3
refrigerant.
Liquid Charging Fitting
Quick Disconnect Fittings
Shutoff Valves
Fire Extinguisher dry-powder fire extinguisher
rated for Class B fires
Ventilation Fan
Note: All tools are suggested to be Spark less tools.
Whirlpool requires and AHAM recommends using a leak
detector during the entire process. If gas or a leak is
detected, stop work and do not use tools that could cause
a spark during operation.
Figure 1
Figure 1: This is an example of a manifold gauge,
vacuum pump combinaon. Figure 2: Typical 6 cfm
vacuum pump without gauges. Figure 3: Vulkan R600a
Cylinder
Figure 2
Figure 3: Vulkan
R 6 0 0 a C y l i n d e r