EasyManua.ls Logo

Whirlpool R600A - Tools and Supplies List

Whirlpool R600A
20 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
GENERAL INFORMATION
R600A Sealed System 2017
n
1-7
Tools & Supplies
Tools & Supplies
• Vacuum Pump; Preferred to have a rating 6 CFM capacity
• Gram measuring Scale
• ¼” High Pressure Hose
• ¼” Low Pressure Hose
• Exclusive manifold gages and hoses should be
used for servicing R600a Appliances. (High, Low, and
Vacuum) Hose requirements for R600a are still being
defined.
• Rubber Charging Hose with “T” Adapter & Shutoff Valve
• 20’ PVC Recovery Hose
• R600a Refrigerant Maximum 420 Gram Cylinder
• Piercing Pliers
• Pinch Off Pliers
• Tubing Cutters
• Rubber Mallet
• Certified and calibrated combustible gas leak detector to
test for leaks if the system is charged with an A2L or A3
refrigerant.
• Liquid Charging Fitting
• Quick Disconnect Fittings
• Shutoff Valves
• Fire Extinguisher dry-powder fire extinguisher
rated for Class B fires
• Ventilation Fan
• Note: All tools are suggested to be Spark less tools.
Whirlpool requires and AHAM recommends using a leak
detector during the entire process. If gas or a leak is
detected, stop work and do not use tools that could cause
a spark during operation.
Figure 1
Figure 1: This is an example of a manifold gauge,
vacuum pump combinaon. Figure 2: Typical 6 cfm
vacuum pump without gauges. Figure 3: Vulkan R600a
Cylinder
Figure 2
Figure 3: Vulkan
R 6 0 0 a C y l i n d e r