FOR SERVICE TECHNICIAN’S USE ONLY
NOTE: This sheet contains important Technical Service Data.
W10590893C Tech Sheet Do Not Remove Or Destroy
Control Assembly
Meter Check of Loads and Fuses
Fuse Service Check:
F1 = Small-triac load fuse
Check operation of loads during Service Diagnostics cycle.
■ If any of the triac loads work, F1 fuse is OK.
■ If all triac loads fail to work, F1 fuse could be open.
See “Fuse Resistance Check.”
Fuse Resistance Check:
1. Unplug dishwasher or disconnect power.
2. Measure resistance of fuse F1.
NOTE: The fuse is on the bottom of the Control Board but can be checked
from the top side. See “Control Pinout” diagram.
■ If resistance is <3 Ω, fuse is OK.
■ If resistance is >3 Ω, replace control.
What To Do If Fuse Open:
Inspect and check resistance of all loads on fuse. If any loads are open,
shorted, or have evidence of overheating or pinched wires, replace loads
and/or repair wires.
DANGER
Electrical Shock Hazard
Only authorized technicians should perform diagnostic
voltage measurements.
After performing voltage measurements, disconnect
power before servicing.
Failure to follow these instructions can result in death
or electrical shock.
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
SPECIFICATIONS
Electrical Supply:
(Under load) 60 Hz, 120 VAC
Lower Spray Arm Rotation:
25 to 40 rpm
Supply Water Flow Rate:
To fill 2 qt (1.9 L) in 27 seconds, 120 psi maximum, 20 psi minimum.
Upper Spray Arm Rotation:
25 to 35 rpm
Supply Water Temperature:
120°F (49°C) (Before starting a cycle, run water from sink faucet until hot.)
REPAIR KITS
Vinyl Touch-up Kits:
675576 (Blue), 676453 (White), 676455 (Gray)
Water Charge:
1.3 gal. (4.8 L) first fill (approximate), 1.1 gal. (4.3 L) other fills
Voltage Measurement Safety Information
When performing live voltage measurements, you must do the following:
■ Verify the controls are in the off position so that the appliance does not start when energized.
■ Allow enough space to perform the voltage measurements without obstructions.
■ Keep other people a safe distance away from the appliance to prevent potential injury.
■ Always use the proper testing equipment.
■ After voltage measurements, always disconnect power before servicing.
Control is
mounted to
console by
snaps along
side and top
and/or screw
tabs along top.
Connector brace locks in connectors.
NOTE: Reinstall brace and box after service if removed.
Pinch to Release
Connector Box (Must release
connector brace to remove box
over power connectors.)
Rotate
Push to Release
Pin 1
Pin 1
Rast Connector Pinout