Troubleshooting
“Built-In” Test Operations and Codes Summery
TYPE OF TEST
CORE BOARD OPERATION)
CHECKING
CODE
NOTE
(USER INTERFACE OPERATION)
Check evaporator de-frost heater 07 Displayed on 2 digit Freezer display
Check fridge probe 06 Displayed on 2 digit Freezer display
Check freezer probe 05 Displayed on 2 digit Freezer display
Check evaporator fan 04 Displayed on 2 digit Freezer display
Check compressor fan 03 Displayed on 2 digit Freezer display
Check damper/air baffle and relay
K008
02 Displayed on 2 digit Freezer display alternatively to the
Check water valve 01 Displayed on 2 digit Freezer display alternatively to the
Check Ice valve
09 Displayed on 2 digit Freezer display alternatively to the
Ice-Maker Sankyo initialization
without Ice-Valve activation
12 Displayed on 2 digit Freezer display alternatively to the
Default thermostatic operation 00 Displayed on 2 digit Freezer display