Loading...
Unité portable pour
récupération / recyclage
de réfrigérant
Manuel dutilisation
Question and Answer IconNeed help?

Do you have a question about the Wigam EASYREC120R100 and is the answer not in the manual?

Summary

Hydraulic diagram

Wiring diagram

Safety precautions and Operation guidelines

Introduction to the recovery unit

Standard equipment and components description

Recovery compressor

Describes the unit's oil-less, air-cooled piston compressor.

Filter

Details the filter with 1/4sae connections and moisture indicator.

Moisture indicator

Explains the function of the moisture indicator for filter quality assessment.

Pressure gauges

Covers the two oil-filled pressure gauges for monitoring suction and discharge lines.

Distillation system

Describes the distillation system for separating oil from refrigerant.

Control panel

Refrigerant recovery from the A;C system

WARNING

Important safety warnings and precautions before starting refrigerant recovery operations.

REFRIGERANT RECOVERY;RECYCLING

Detailed procedure for performing refrigerant recovery and recycling tasks.

REFRIGERANT RECOVERY

Specific step-by-step instructions for the refrigerant recovery process.

Self-Purge Method

WARNING

Cautionary note regarding filter drier usage with different types of refrigerants.

PURGE FUNCTION

Instructions for using the unit's purge function to remove residual refrigerant.

Refrigerant Transfer with Push-Pull method

WARNING

Details on connecting the unit and circuit for rapid liquid refrigerant transfer.

REFRIGERANT TRANSFER

Step-by-step guide for transferring refrigerant using the push-pull method.

Recovery cylinder cooling method

PRE-WORK COOLING METHOD

Procedure outlining steps for cooling the recovery cylinder before operation.

CYLINDER COOLING PROCEDURE IN THE RECOVERING PROCESS

Procedure for cooling the cylinder during the actual refrigerant recovery process.

Ordinary maintenance

SPARE PARTS AND ACCESSORIES

Lists recommended spare parts and optional accessories for the unit.

PERIODICAL OPERATIONS FOR ORDINARY MAINTENANCE

Describes routine maintenance tasks and recommended replacement schedules.

Max pressure switch reset

Technical features

Troubleshooting

Wigam EASYREC120R100 Specifications