Loading...
Sistemi e strumenti per condizionamento e refrigerazione
Air conditioning and refrigeration systems and instruments
Anlagen und Geräte für Klima- und Kälteanlagen
Systèmes et instruments pour conditionnement et refrigération
Sistemas e instrumentos para el acondicionamiento y refrigeración
Numero di serie
Serial number
Seriennummer
Numéro de série
Número de serie
P2
Pompe per alto vuoto
Istruzioni d'uso e manutenzione
High vacuum pumps
User and service manual
Hochvakuumpumpen
Betriebs- und Wartungsanleitung
Pompes à haut vide
Mode d'emploi et maintenance
Bombas de alto vacío
Instrucciones de uso y mantenimiento
Question and Answer IconNeed help?

Do you have a question about the Wigam P2D and is the answer not in the manual?

Summary

WIGAM High Vacuum Pumps

Safety Precautions

General Safety Guidelines

Summarizes essential safety points for operating and handling vacuum pumps, including personal protection and environmental care.

Introduction to WIGAM High Vacuum Pumps

General Performance and Technical Data

Provides key specifications for WIGAM high vacuum pumps, including swept volume, ultimate vacuum, power, and operating temperatures.

Gas Ballast Valve

Explains the function of the gas ballast valve, which aids starting and prevents vapor condensation in the lubricant.

Installation

Oil Filling

Details the mandatory procedure for filling the pump with the correct type and amount of oil before operation.

Suction Connection

Discusses suction connection best practices for efficient vacuum pull and optional check valve integration.

Discharge Connection

Covers discharge connection options, including free air discharge or using an oil trap plug for specific applications.

Installation Details

Electric Hooking and General Precautions

Covers electrical connection requirements, rotation check, thermal protection, grounding, and general placement precautions.

Pump Use

Pump Start and Stop Procedures

Outlines the correct steps for starting and stopping the vacuum pump, including pre-operation checks and shutdown sequences.

Routine Maintenance

Lubrication and Oil Changing

Details the recommended oil types, viscosity, and the schedule for lubrication and oil changes for pump longevity.

Extraordinary Maintenance

Disassembly Instruction

Describes when to perform extraordinary maintenance and notes that disassembly is for skilled staff only.

Spare Parts

Ordering Spare Parts

Instructions on how to order spare parts by specifying the pump model and the reference number of the required part.

Wigam P2D Specifications

General IconGeneral
Power550W
Flow rate50L/min
Frequency50 Hz
Inlet/Outlet Size1 inch
Voltage220-240V