EasyManua.ls Logo

WIKA 55 Series User Manual

WIKA 55 Series
84 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
DE
EN
Operating instructions
Betriebsanleitung
Mode d'emploi
Manual de instrucciones
ES
FR
Model R5502 Model S5550
Bimetal thermometer, model 55
Bimetallthermometer, Typ 55
Thermomètre bimétallique, type 55
Termómetro bimetálico, modelo 55
Question and Answer IconNeed help?

Do you have a question about the WIKA 55 Series and is the answer not in the manual?

WIKA 55 Series Specifications

General IconGeneral
TypeBimetallic thermometer
Case MaterialStainless steel
Accuracy±1% of full scale
Temperature Range-70°C to +540 °C
Connection1/2" NPT
Window MaterialGlass
Scale DivisionDependent on temperature range
Dial Size63 mm, 80 mm, 100 mm, 125 mm, 160 mm

Summary

General information

Design and function

2.1 Overview

Illustrates and labels the main parts of the bimetal thermometer models.

2.2 Description

Describes the materials used and the intended installation environments for the thermometers.

2.3 Scope of delivery

Instructions for verifying the contents of the delivery against the packing list.

Safety

3.1 Explanation of symbols

Defines the meaning of warning and informational symbols used throughout the manual.

3.2 Intended use

Specifies the primary applications and purpose of the bimetal thermometers.

3.3 Improper use

Highlights hazardous situations and injuries resulting from incorrect usage.

3.4 Responsibility of the operator

Outlines the operator's legal and safety obligations for instrument use.

3.5 Personnel qualification

Stresses the importance of skilled personnel and the risks associated with unqualified operation.

Skilled personnel

Defines the qualifications and expertise required for personnel handling the instrument.

3.6 Personal protective equipment

Lists and describes the essential personal protective equipment (PPE) for safe operation.

3.7 Labelling, safety marks

Presents an example product label and explains its various markings and safety indicators.

Transport, packaging and storage

4.1 Transport

Instructions for checking and reporting transport damage, and handling during transit.

4.2 Packaging and storage

Recommendations for preserving packaging and conditions for storage to maintain instrument integrity.

Commissioning, operation

5. Commissioning, operation

Covers initial setup, operational safety, and handling of hazardous media or conditions.

5.1 Use of thermowells

Explains proper installation and use of thermowells to prevent instrument damage.

5.2 Thermal contact medium

Details the application of thermal contact medium and related safety warnings.

Faults

6. Faults

General advice on identifying faults and initial troubleshooting steps.

Maintenance and cleaning

7.1 Maintenance

States the maintenance-free nature of the thermometers and required periodic checks.

7.2 Cleaning

Provides safe procedures and warnings for cleaning the instrument.

Dismounting, return and disposal

8.1 Dismounting

Details safe methods for removing the instrument, including hot media and electrical hazards.

8.2 Return

Guidelines for preparing and shipping instruments back to WIKA, including cleaning requirements.

8.3 Disposal

Recommendations for environmentally responsible disposal of the instrument and its components.

Specifications