12 WIKA additional operating instructions model 55 (ATEX)
10) Ignition hazard analysis
Relevant identied
ignition hazards
Implemented protective measures
Hot surfaces
Actual surface temperature depends on
application; media temperature only
Temperature range marking; T range marking
Observation of legibility of marking
Information given in operation instructions
Mechanically
generated sparks and
hot surfaces
Low contact speed
Limitation of vibration
Selection of suitable materials
Information given in operation instructions
Stray electric currents,
cathodic corrosion
protection
Grounding via process connection required
Information given in operation instructions
Static electricity
No propagating brush discharge
All conductive parts bonded
Limitation of projected area of non-conductive
parts
Limitation of layer thickness of
non-conductive parts
Grounding via process connection required
Description of cleaning process
Information given in operation instructions
Exothermic reactions,
including self-ignition
of dusts
Provision of material data of the wetted parts
for the customer in order to avoid the use of
critical media
Information given in operation instructions
11) The legibility of the marking must be observed during time in use
but at least during inspection periods of three years. If any harm
of the legibility is found please contact the manufacturer to renew
the marking.
12) Due to potential ignition hazards (e.g. static discharge), the
packaging material and the desiccant bag must not be put in the
hazardous area.
13) Permissible operating pressure at the stem: max. 25 bar [360 psi],
static
3. Special conditions for use (X conditions)