9WIKA operating instructions pressure gauge model 7 per ATEX
2080284.08 02/2021 EN/DE/FR/ES
EN
Before mounting and commissioning the instrument, ensure
you read the operating instructions!
The instrument bearing this mark is a safety pressure gauge with a
solid bae wall in accordance with EN 837.
2.6 Special conditions for safe use (X conditions)
Pressure surges must be avoided at all costs. Open the shut-o valves slowly.
Temperature increases due to compression warming absolutely must be taken
into account. In these cases it may be necessary to throttle the rate of change
of pressure or reduce the permissible medium temperature.
The end user must ensure that the instrument is connected to the equipotential
bonding of the end-use application via the process connection. The sealings
used at the process connection must be electrically conductive. Alternatively,
take other measures for grounding.
Avoid handling substances that might react dangerously with the materials of
the instrument.
Avoid handling substances that are liable to spontaneous combustion.